Results 121 to 130 of about 830 (155)
Some of the next articles are maybe not open access.
Coherence loss minimization in SAR interferometric registration
IEEE International Geoscience and Remote Sensing Symposium, 2003A comparative study regarding the interpolation of stochastic electromagnetic band-limited signals in synthetic aperture radar (SAR) interferometry is detailed. It is shown that the most appropriate interpolation scheme to minimize the coherence losses is the one based on the Knab Sampling Window kernel.
Maurizio Migliaccio, Felice Bruno
openaire +2 more sources
Interferometric coherence of SAR signals backscattered by a building
IEEE International IEEE International IEEE International Geoscience and Remote Sensing Symposium, 2004. IGARSS '04. Proceedings. 2004, 2004In this paper we analytically evaluate the correlation coefficient between the signals backscattered towards two spatially separated antennas by a building modelled as a parallelepiped over a possibly rough terrain. We consider both single and multiple scattering contributions.
FRANCESCHETTI, GIORGIO +3 more
openaire +2 more sources
Phase retrieval in low-coherence interferometric microscopy
Optics Letters, 2007We present compensating methods that address inherent errors in quantitative phase reporting for low-coherence interferometric techniques. A brief theoretical treatment of the problem and experimental validation using spectral domain phase microscopy demonstrate mitigation of the degrading effects of phase leakage on accurate measurement of optical ...
Audrey K, Ellerbee, Joseph A, Izatt
openaire +2 more sources
Selective interferometric sensing by the use of coherence synthesis
Optics Letters, 1987A technique is discussed and demonstrated whereby the sensitivity of an imbalanced fiber-optic interferometric sensor is changed by as much as 70 dB by modifying the power spectrum and thus the coherence function of the input optical source. This phenomenon is then extended and used to monitor selectively single sensors in a small fiber-optic ladder ...
R C, Youngquist +2 more
openaire +2 more sources
Low Coherence Interferometric Technique
2001We propose an original technique based on low coherence interferometry to detect objects in strongly scattering media. In order to use broadband light, a special interferometer called the SISAM correlator is used to allow coherent superposition of the reference and tested beams.
G. Brun +4 more
openaire +1 more source
Effects of source coherence on low coherence interferometric imaging
Proceedings of the IEEE 26th Annual Northeast Bioengineering Conference (Cat. No.00CH37114), 2002Optical coherence tomography (OCT) is an important imaging technique for medical applications. In this work we report our results on imaging of periodontal tissue. Our OCT system utilizes an erbium doped fiber amplifier emitting near 1.55 /spl mu/m as the source. The coherence length of the source can be varied by more than a factor of 5 by varying the
null Daqing Piao +4 more
openaire +1 more source
Interferometric sensor based on coherent imaging of gratings
Applied Optics, 2003A sensitive interferometric sensor scheme that is based on coherent imaging of a first phase grating onto a second phase grating, their periods accurately matched, is suggested. Experimental data, obtained with a setup based on the suggested scheme, are presented.
Anders, Magnusson +2 more
openaire +2 more sources
Polarimetric and interferometric characterization of coherent scatterers in urban areas
IEEE Transactions on Geoscience and Remote Sensing, 2006In this paper the concept of point-like coherent scatterers (CSs) in urban areas is introduced. The detection of CSs in single and quad-polarized images is addressed and applied on polarimetric and interferometric high-resolution airborne SAR data at L-band. For the detection of CSs two different approaches are proposed and their individual performance
Rafael Zandona-Schneider +3 more
openaire +3 more sources
Design of a coherent optical interferometric system
SPIE Proceedings, 2006A 100-mm-aperture high lateral resolution interferometer has been developed in Fine Optical Engineering Research Center (FOERC), which is applied to the measurement of spatial frequencies of up to 2.5 lines/mm over a 100mm field of view. The system transfer function of the interferometer is greater than 60% at near half the Nyquist frequency.
Jiancheng Xu +4 more
openaire +1 more source
Interferometric studies of coherence in a powder laser
Optical Materials, 1999Abstract Longitudinal and transversal coherence in powder laser emission was studied using two different interferometric techniques. It has been shown that longitudinal coherence length in Nd0.5La0.5Al3(BO3)4 powder (ceramics) laser emission corresponds to 0.7 A linewidth.
M.A. Noginov +4 more
openaire +1 more source

