Results 61 to 70 of about 201 (163)
This paper proposes an effective detection method for insulated gate bipolar transistor (IGBT) open‐circuit faults in multiple modular multilevel converters (MMCs) working in inverter and rectifier modes. This fault detection uses segmental structure and is composed of the fault monitoring and fault confirmation.
Zhengkui Zhao, Minxiao Han
wiley +1 more source
Impedance‐Based Adaptive Droop Control for Islanded AC Microgrids and Overview
Recent improvements in the application of distributed energy resources (DERs) and microgrids (MGs) have made controlling these resources very important. However, there are still many challenges in this field. One of the anticipated challenges in islanded MGs (IMGs) is the mismatched output impedance of DERs, which affects the volt‐var regulation ...
Forough Qashqaie +4 more
wiley +1 more source
In grid‐connected smart distribution systems, the prediction and mitigation of flicker caused by harmonics and interharmonics present a significant challenge for stable grid operation, particularly in the presence of distributed renewable energy sources (DRESs).
Shree Ram Senthil Subramani +2 more
wiley +1 more source
In the steel industry, electric arc furnaces (EAFs) are essential for metal scrap recycling. However, they are known for their high reactive power consumption, negatively impacting power quality (PQ). The static VAR compensator (SVC) is the reactive power compensation device that provides the best cost‐benefit relation for mitigating the impact of EAFs.
J. Marulanda-Durango +3 more
wiley +1 more source
The cross‐correlation technique was used in this study to recover the complex, aperiodic, asymmetric, and non‐linear properties of the signals during cross‐country faults with high impedance fault syndrome. Due to its reduced sensitivity to background fluctuations, a given change may not affect all of the component peaks.
Pampa Sinha +6 more
wiley +1 more source
LADRC‐based non‐characteristic harmonic suppression strategy for pumped storage power plants
This letter proposes a control strategy based on linear active disturbance rejection control (LADRC) to alleviate the delay triggering angle α non‐characteristic harmonics caused by transient disturbances. The validity of the conclusion was verified through on‐site data collection, theoretical analysis, and simulation verification.
Zheng Lan +4 more
wiley +1 more source
A High-Speed Master-Slave ADALINE for Accurate Power System Harmonic and Inter-Harmonic Estimation
This paper presents a unique two-fold adaptive linear neural network (ADALINE) for fast and accurate measurement of fundamental, harmonics, sub-harmonics, inter-harmonics and decaying DC components of a distorted current signal with additive noise.
Priyabrat Garanayak +2 more
doaj +1 more source
Evaluation of Waveform Distortion in BESS-Integrated Fast-Charging Station
This paper presents a detailed, measurement-based assessment of interharmonic, harmonic, and supraharmonic emissions from a Battery Energy Storage System (BESS) supporting electric vehicle (EV) fast charging.
Manav Giri, Sarah Rönnberg
doaj +1 more source
The dc link of dual pulse width modulation (PWM) adjustable speed drives (ASDs) is coupled with inverter-motor-drive systems (IMDs) and grid-side converters, forming a multi-coupled system that complicates grid stability analysis beyond that of ...
Dirui Yang +4 more
doaj +1 more source
The calculation of characteristic frequency of rolling bearing fault is the important theory basis for rolling bearing fault diagnosis and condition monitoring all the time.
Sun Xianbin, Tan Jiwen, Wen Yan
doaj