Results 61 to 70 of about 946 (192)
Input current interharmonics in adjustable speed drives caused by fixed-frequency modulation techniques [PDF]
© 2016 IEEE. Adjustable Speed Drives (ASDs) based on double-stage conversion systems may inject interharmonics distortion into the grid, other than the well-known characteristic harmonic components.
H. Soltani (23448211) +4 more
core +2 more sources
Modern protection relays require accurate and fast phasor estimation under harsh transient conditions, including a decaying DC component, harmonics, interharmonics, noise, and frequency instability.
Natheer Alwan, Veljko Papic
doaj +1 more source
New Power Balance Equations for Modelling Electric Arc Furnace
‐ Proposing two new power balance equations which consider both arc radius and length. ‐ Proposing four new EAF models. ‐ Time varying characteristics of the model are preserved as model parameters change every half cycle. ‐ Like the actual cases, the time variations are non‐stationary as different ARMA models are selected at every run of the models. ‐
Zahra Babaei +2 more
wiley +1 more source
Fast-responding measurements of power system harmonics using discrete and fast fourier transforms with low spectral leakage [PDF]
Conventional wisdom dictates that a Fast Fourier Transform (FFT) will be a more computationally effective method for measuring multiple harmonics than a Discrete Fourier Transform (DFT) approach.
Burt, Graeme M. +3 more
core
Research on Vibration and Noise of Converter Transformer Based on LCL Converter
The paper outlines the topology of the new LCL converter. Through theoretical analysis and experimental verification, it has been confirmed that the proposed LCL converter not only effectively sup‐presses harmonics but also significantly reduces the vibration and noise of the converter transformers.
Liang Zhao +5 more
wiley +1 more source
Operation of an induction motor supplied by voltage with interharmonics [PDF]
W artykule omówiono skutki obecności interharmonicznych, tj. częstotliwości wyższych od częstotliwości podstawowej harmonicznej, niebędących jej całkowitą krotnością, w napięciu zasilającym silnik indukcyjny.
Drabek, T.
core +1 more source
This paper proposes an effective detection method for insulated gate bipolar transistor (IGBT) open‐circuit faults in multiple modular multilevel converters (MMCs) working in inverter and rectifier modes. This fault detection uses segmental structure and is composed of the fault monitoring and fault confirmation.
Zhengkui Zhao, Minxiao Han
wiley +1 more source
Effect of Rectangular Voltage Fluctuations on Currents of Single-Phase Induction Motors
Various power quality disturbances commonly occur in a power system, including voltage fluctuations. These can be analysed as simultaneous occurrences of voltage subharmonics and interharmonics of various frequencies – components of frequency less than ...
Marcin Pepliński, Piotr Gnaciński
doaj +1 more source
Line commutated converter (LCC) has been widely applied in hybrid high voltage direct current (HVDC) transmission system, where the modular multilevel converter (MMC) is applied as receiving end and may induce low order harmonics in DC-link voltage ...
He Huang +5 more
doaj +1 more source
Impedance‐Based Adaptive Droop Control for Islanded AC Microgrids and Overview
Recent improvements in the application of distributed energy resources (DERs) and microgrids (MGs) have made controlling these resources very important. However, there are still many challenges in this field. One of the anticipated challenges in islanded MGs (IMGs) is the mismatched output impedance of DERs, which affects the volt‐var regulation ...
Forough Qashqaie +4 more
wiley +1 more source

