Results 181 to 190 of about 60,244 (309)

Efficient Interleaved Multi-Band Outer Volume Suppression for Highly Accelerated Simultaneous Multi-Slice Imaging of the Heart. [PDF]

open access: yesBioengineering (Basel)
Arami A   +9 more
europepmc   +1 more source

Shakespeare Interleaved

open access: yes, 2013
At the end of my post on the collection of Richard Warner's notes in the Beinecke, I mentioned that his editions of Shakespeare, complete with working notes on interleaved pages, had been digitised and was available online.
James Harriman Smith
core  

Multiple‐TE Based Blood–Brain‐Barrier Water Exchange Time Measurement Using a TE‐Resolved 3D TSE Stack‐Of‐Spirals Readout

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To develop a slice‐wise blurring‐free and densely sampled TE‐resolved multiple‐TE (mTE) ASL sequence (TASL) for measuring blood–brain barrier (BBB) water exchange time. Methods A 3D TSE spiral‐readout pCASL sequence was modified to enable TE‐resolved acquisition.
Bo Li   +11 more
wiley   +1 more source

A Modified Balanced Steady State Free Precession Sequence for Overhauser Magnetic Resonance Imaging

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose Low‐ and ultralow‐field magnetic resonance imaging (ULF MRI) have inherently low signal‐to‐noise ratio (SNR) by design. Overhauser dynamic nuclear polarization (ODNP) stands out as an effective solution for continuous signal enhancement.
Kai Buckenmaier   +9 more
wiley   +1 more source

Visual and tactile motion cues enhance the categorisation of novel object shapes. [PDF]

open access: yesExp Brain Res
Seveso MA   +4 more
europepmc   +1 more source

Blind Estimation Versus Direct Measurement of the Arterial Input Function in Dynamic Contrast‐Enhanced MRI of the Breast

open access: yesMagnetic Resonance in Medicine, EarlyView.
Purpose Accurate arterial input functions (AIFs) are essential for quantitative dynamic contrast‐enhanced (DCE) MRI, yet direct measurement is challenging and population‐averaged AIFs neglect patient‐specific variability. Blind deconvolution provides an alternative by estimating patient‐specific AIFs directly from tissue data, up to a scale factor ...
Jake L. Cray   +4 more
wiley   +1 more source

A Sub‐Microsecond Switch Enabling SWIFT 23Na Imaging at 10.5 T

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To enable sodium SWIFT imaging, which is a zero‐echo time imaging technique, at ultra‐high magnetic fields through the development of custom electronics hardware, and to showcase this capability with in vivo imaging results. Methods The custom hardware developed consists of a high‐speed optical trigger with 10 ns resolution, an in‐bore
Russell L. Lagore   +10 more
wiley   +1 more source

Home - About - Disclaimer - Privacy