Results 101 to 110 of about 5,399 (273)
ABSTRACT Purpose To deconvolve cardiac phase and hemodynamic effects in hyperpolarized (HP) [1‐13C]pyruvate and to develop a cardiac phase‐adjustable reconstruction framework. Methods Cardiac phase drift during dynamic acquisition of HP 13C MRS and its effect on dynamic signal fidelity were simulated using a digital cardiac phantom. A hemodynamic model
Sung‐Han Lin +5 more
wiley +1 more source
Application of interleaved bridgeless boost PFC converter without current sensing
Interleaved bridgeless boost power factor correction (PFC) converter based on predictive control method without any current sensing is presented in this paper.
I. Iskender +6 more
core +1 more source
Ultrafast fMRI Detects Age‐Related Changes in Harmonics of Cardiac Pulsations in the Brain at 7 T
ABSTRACT Purpose Aging impacts pulsatility of blood vessels in the brain, reflecting vascular health. Resolving characteristics of cardiac pulsatility requires faster acquisitions than traditional fMRI. An ultrafast fMRI method was developed and applied to sample several harmonics of cardiac pulsations at 7 T.
Charles Marchini +5 more
wiley +1 more source
Single‐stage ZVS boost integrated push–pull power factor correction converter
This study proposes a cutting‐edge AC/DC converter designed for medium‐power PFC applications. The converter is a single‐phase, single‐stage boost‐push–pull model.
Hamed Nazemi Sejzi, Ehsan Adib
doaj +1 more source
Purpose Accurate arterial input functions (AIFs) are essential for quantitative dynamic contrast‐enhanced (DCE) MRI, yet direct measurement is challenging and population‐averaged AIFs neglect patient‐specific variability. Blind deconvolution provides an alternative by estimating patient‐specific AIFs directly from tissue data, up to a scale factor ...
Jake L. Cray +4 more
wiley +1 more source
A Sub‐Microsecond Switch Enabling SWIFT 23Na Imaging at 10.5 T
ABSTRACT Purpose To enable sodium SWIFT imaging, which is a zero‐echo time imaging technique, at ultra‐high magnetic fields through the development of custom electronics hardware, and to showcase this capability with in vivo imaging results. Methods The custom hardware developed consists of a high‐speed optical trigger with 10 ns resolution, an in‐bore
Russell L. Lagore +10 more
wiley +1 more source
ABSTRACT Purpose Magnetic resonance spectroscopy techniques are widely used to non‐invasively study brain metabolism. Despite advances in magnetic resonance spectroscopic imaging (MRSI), there is a notable absence of research on comparing fast non‐Cartesian MRSI with single‐voxel spectroscopy (SVS), limiting our understanding of its performance and ...
Young Woo Park +3 more
wiley +1 more source
Design of a robust digital current controller for a grid connected interleaved inverter
This paper is concerned with the design and practical implementation of a robust digital current controller for a threephase voltage source grid-connected interleaved inverter.
Sharkh, S. M., Abu-sara, M. A.
core
This paper proposes a novel approach to address the issues of imbalanced 2-phase resonant currents and output currents in traditional 2-phase parallel LLC resonant converters, as well as the excessive output current ripple caused by the conventional 2 ...
Haichao Li +4 more
doaj +1 more source
View Order With Arbitrary Center Echoes
ABSTRACT Purpose To provide explicit, vendor‐independent view‐order constructions that enable selection of an arbitrary center echo in multi‐shot imaging, with a focus on RARE and MPRAGE. Methods Vendor‐independent view‐order methods were developed to assign echo and shot indices to a prescribed set of phase encodes, enabling explicit selection of the ...
Henric Rydén +4 more
wiley +1 more source

