Novel Fault Protection Method for Flexible DC Power Systems
A fault protection method is proposed for flexible direct-current (DC) power systems based on the cosine similarity of currents in current-limiting reactors.
Genqi Chen +7 more
doaj +1 more source
Detailed Simulation of Transformer Internal Fault in Power System by Diakoptical Concept
This paper presents a novel method for modeling internal faults in a power transformer. This method uses a distributed computing approach for analysis of internal fault in transient stability (T/S) studies of electrical networks using Diakoptics and ...
KOUHSARI, S. M., KOOCHAKI, A.
doaj +1 more source
Shear behavior of bedding fault material on the basal layer of DGB landslide
Daguangbao (DGB) Landslide (12 × 108 m3) is the largest landslide triggered by the 2008 Ms8.0 Wenchuan Earthquake, in which basal shear failure develops on an interlayer fault at 400 m deep under the ground.
Yufei Liang +5 more
doaj +1 more source
Fault Diagnosis for Modular Multilevel Converter Switching Devices via Multimodal Attention Fusion
Modular multilevel converters (MMCs) have been widely applied in high voltage direct current (HVDC) transmission project, and security is their fundamental issue.
Longzhang Ke +3 more
doaj +1 more source
The reliability and stability of differential protection in power transformers could be threatened by several types of inferences, including magnetizing inrush currents, current transformer saturation, and overexcitation from external faults.
Sopheap Key, Gyu-Won Son, Soon-Ryul Nam
doaj +1 more source
Probabilistic sensitivity analysis of two suspension bridges in Istanbul, Turkey to near- and far-fault ground motion [PDF]
The aim of this paper is to compare the near-fault and far-fault ground motion effects on the probabilistic sensitivity dynamic responses of two suspension bridges in Istanbul.
Ö. Çavdar
doaj +1 more source
Accurate classification between magnetizing inrush currents and internal faults is essential for reliable transformer protection and stable power system operation. Because their transient waveforms are so similar, conventional differential protection and
Heungseok Lee +2 more
doaj +1 more source
As a special type of fracture-cavity carbonate reservoir, fault/fracture-controlled paleokarsts are affected by large strike-slip faults with various storage spaces, irregular geometry, and stochastic spatial distribution, which brings new challenges to ...
Wenbiao Zhang +6 more
doaj +1 more source
Crosstalk between the ribosome quality control‐associated E3 ubiquitin ligases LTN1 and RNF10
Loss of the E3 ligase LTN1, the ubiquitin‐like modifier UFM1, or the deubiquitinating enzyme UFSP2 disrupts endoplasmic reticulum–ribosome quality control (ER‐RQC), a pathway that removes stalled ribosomes and faulty proteins. This disruption may trigger a compensatory response to ER‐RQC defects, including increased expression of the E3 ligase RNF10 ...
Yuxi Huang +8 more
wiley +1 more source
The dependability and security of transformer differential protection can be compromised by current transformer (CT) saturation, which distorts current measurements and may lead to the maloperation of protective relays.