Results 41 to 50 of about 6,696 (227)
Long Fiber Type Carbon Fiber Reinforced Plastic Pedicle Screws Exhibit High Strength, Comparable to Titanium-Alloy Screws, and Are Resistant to Loosening [PDF]
Objective To develop a pedicle screw for posterior spinal fixation using this long fiber carbon fiber reinforced plastic (CFRP) technology and evaluate its strength and radiolucency compared with titanium (Ti)-alloy screws.
Kohei Morita +6 more
doaj +1 more source
Study design A single-institution, retrospective cohort study. Objective To compare the accuracy and short-term clinical outcomes of pedicle screw placement between robot-assisted (RA) and freehand (FH) technique in the treatment of adult degenerative ...
Xiuyuan Chen +10 more
doaj +1 more source
Treatment Trade‐Offs and Choices for Femoral Fractures: A Systematic Review and Meta‐Analysis
This review examines the trade‐offs between surgical intervention and traction therapy for adult and elderly patients with femoral fractures and surgical contraindications, particularly in resource‐limited settings. While intramedullary nailing may offer better clinical outcomes, traction therapy is often preferred due to limited surgical resources ...
Jiarui Li +11 more
wiley +1 more source
Distally based sural fasciomusculocutaneous flap for treatment of wounds of the distal third of the leg and ankle with exposed internal hardware [PDF]
Soft tissue reconstruction of the distal third of the lower limb with exposure of the internal hardware is a challenging problem with several potential complications, such as exposure of the fracture line, fracture instability and bacterial contamination.
Luca Vaienti +4 more
core +1 more source
Four patients with severe wrist destruction from various causes were treated with customized 3D‐printed prostheses. In addition to the specific articular surface matching their original radiocarpal joint, two innovative proximal component designs were created to address different bone defects.
Qipei Wei +3 more
wiley +1 more source
Abstract Objective To describe a novel, coaptationless surgical technique for the treatment of multiligament stifle injuries (MLSI). Study design Retrospective case series. Animals A total of 23 cats presenting with a rupture of two or more ligaments stabilizing the stifle.
Sebastian C. Knell +2 more
wiley +1 more source
The fixator is a medical device that provides support to fractured biological structures. Metal biomaterials are mainly used for replacing broken or damaged hard tissues such as bones because of their high strenght, toughness and corrosion resistance ...
Dalibor Milojko Đenadić +4 more
doaj +1 more source
SUMMARY A 17‐year‐old, 24‐kg, female greater rhea (Rhea americana) presented with an acute onset of left wing droop. Clinical examination and radiographs revealed an open, simple, displaced, short‐oblique diaphyseal fracture of the distal third of the left humerus.
Pierre Huberdeau +6 more
wiley +1 more source
Complicated tibia fractures are still connected with significant problems of healing. Hence, the external Ilizarov fixators are applied, and then they are sometimes converted to internal fixators.
Szeliga Jiří +4 more
doaj +1 more source
TOpic: rare and special cases, the real "Strange cases" [PDF]
Introduction: The bladder hernia represents approximately 1-3% of all inguinal hernias, where patients aged more than 50 years have a higher incidence (10%).
AUTIERI, DOMENICO +48 more
core +1 more source

