Results 201 to 210 of about 4,072,286 (225)
Some of the next articles are maybe not open access.
Floating flap of internal limiting membrane in myopic macular hole surgery
Graefe's Archive for Clinical and Experimental Ophthalmology, 2018To evaluate the surgical results of macular hole (MH) in patients with high myopia treated with pars plana vitrectomy (PPV) leaving the internal limiting membrane (ILM) flap floating in vitreous fluid at the edge of the MH.Nine highly myopic eyes with MH of nine consecutive patients who underwent PPV were retrospectively evaluated.
Kenji Yamashiro +5 more
openaire +2 more sources
Retina, 2022
Purpose: To evaluate the anatomical and functional outcomes of internal limiting membrane (ILM) peeling and the inverted ILM flap technique for rhegmatogenous retinal detachment coexisting with macular hole. Methods: This retrospective study evaluated the medical records of 79 eyes ...
Xujia, Liu +8 more
openaire +2 more sources
Purpose: To evaluate the anatomical and functional outcomes of internal limiting membrane (ILM) peeling and the inverted ILM flap technique for rhegmatogenous retinal detachment coexisting with macular hole. Methods: This retrospective study evaluated the medical records of 79 eyes ...
Xujia, Liu +8 more
openaire +2 more sources
Modified inverted internal limiting membrane flap technique for macular hole closure
Japanese Journal of Ophthalmology, 2022To investigate the efficacy of modified internal limiting membrane (ILM) flap technique combined with vitreous surgery for treating macular holes and examine the outcomes in visual function and anatomic macular hole closure.Retrospective, observational.Between July 1, 2015, and October 1, 2019, the modified inverted ILM flap technique combined with ...
Sayaka, Kakehi +3 more
openaire +2 more sources
Inverted internal limiting membrane flap technique for very large macular hole
To assess the anatomical and visual outcome of idiopathic macular holes greater than 1000 µm using the inverted internal limiting membrane flap technique.This retrospective case series included 5 eyes of 5 patients with idiopathic macular hole with base diameter greater than 1000 µm who underwent inverted internal limiting membrane flap technique along
Raja Narayanan
exaly +3 more sources
INVERTED INTERNAL LIMITING MEMBRANE FLAP TECHNIQUES AND OUTER RETINAL LAYER STRUCTURES
Retina, 2020Purpose: To examine the influence of the inverted flap (IF) internal limiting membrane (ILM) technique in macular hole (MH) closure on outer retinal layers after MH surgery. Methods: Retrospective study.
Mun Yueh, Faria +5 more
openaire +2 more sources
International Ophthalmology, 2019
To compare the anatomical and functional outcomes of the inverted internal limiting membrane (ILM) flap technique and the autologous blood clot (ABC) to ILM insertion technique for the repair of refractory macular hole (RMH).Fifty-two consecutive patients (52 eyes) diagnosed with RMH with a minimum diameter more than 700 µm were enrolled.
Zhixiang Hu +3 more
openaire +2 more sources
To compare the anatomical and functional outcomes of the inverted internal limiting membrane (ILM) flap technique and the autologous blood clot (ABC) to ILM insertion technique for the repair of refractory macular hole (RMH).Fifty-two consecutive patients (52 eyes) diagnosed with RMH with a minimum diameter more than 700 µm were enrolled.
Zhixiang Hu +3 more
openaire +2 more sources
Macular hole reopening after inverted internal limiting membrane flap
Journal of Case Reports and Images in Ophthalmology, 2022Introduction: Here, we present a case of macular hole (MH) reopening after an initial successful closure with an inverted internal limiting membrane (ILM) flap procedure. Case Report: The patient was a 72-year-old Hispanic male who presented with decreased vision in the right eye who was found to have a 431 μm, full-thickness ...
Hossein Ameri +2 more
openaire +1 more source
Pedicle Internal Limiting Membrane Transposition Flap Technique for Refractory Macular Hole
Ophthalmic Surgery, Lasers and Imaging Retina, 2015BACKGROUND AND OBJECTIVE: To determine the efficacy of the pedicle internal limiting membrane (ILM) transposition flap technique for refractory macular holes (MHs) in which the inverted ILM flap technique cannot be performed. PATIENTS AND METHODS:
Tamaki, Gekka +6 more
openaire +2 more sources
Retina
Purpose: To compare the anatomical and functional outcomes of the inverted internal limiting membrane (ILM) flap technique and ILM insertion technique for the treatment of large macular holes (MHs).
Miao, Zeng, Chunyan, Cai, Xiao, Chen
openaire +2 more sources
Purpose: To compare the anatomical and functional outcomes of the inverted internal limiting membrane (ILM) flap technique and ILM insertion technique for the treatment of large macular holes (MHs).
Miao, Zeng, Chunyan, Cai, Xiao, Chen
openaire +2 more sources
The Cloverleaf Internal Limiting Membrane Flap Technique for Repair of Challenging Macular Holes
RetinaPurpose: This study introduces the cloverleaf internal limiting membrane (ILM) flap technique for managing challenging macular holes, aiming to enhance ILM flap placement and improve functional and anatomical outcomes.
Tina Felfeli +3 more
openaire +2 more sources