Continuous Glucose Monitor Failure Following Exposure to High‐Output LED‐Based Photography

open access: yes
JDDG: Journal der Deutschen Dermatologischen Gesellschaft, EarlyView.
Lennart Ocker‐Serger   +4 more
wiley   +1 more source

Flap Monitoring Using Interstitial Fluid Glucose Measurements

Plastic Surgery, 2022
Background: Various flap monitoring techniques have been used in the early detection of anastomotic thrombus; however, the use of automatic and continuous monitoring methods is presently uncommon. The purpose of this study was to investigate trends in interstitial fluid glucose concentration (IFG) in flap monitoring by measuring IFG automatically and ...
Tomoki Kiuchi   +6 more
openaire   +2 more sources

Can Interstitial Glucose Assessment Replace Blood Glucose Measurements?

Diabetes Technology & Therapeutics, 2000
Current treatment regiments for individuals depending on exogenous insulin are based on measurements of blood glucose obtained through painful finger sticks. The shift to minimal or noninvasive continuous glucose monitoring primarily involves a shift from blood glucose measurements to devices measuring subcutaneous interstitial fluid (ISF) glucose.
K, Rebrin, G M, Steil
openaire   +2 more sources

Interstitial glucose concentration and glycemia: implications for continuous subcutaneous glucose monitoring

American Journal of Physiology-Endocrinology and Metabolism, 2000
The changes in plasma glucose concentration and in interstitial glucose concentration, determined with a miniaturized subcutaneous glucose sensor, were investigated in anesthetized nondiabetic rats. Interstitial glucose was estimated through two different calibration procedures. First, after a glucose load, the magnitude of the increase in interstitial
B, Aussedat   +5 more
openaire   +2 more sources

Accurate estimate of Blood Glucose through Interstitial Glucose by Genetic Programming

2017 IEEE Symposium on Computers and Communications (ISCC), 2017
Subjects suffering from Type 1 diabetes mellitus need to constantly receive insulin injections. To improve their life quality, a desirable solution is represented by the implementation of an artificial pancreas. In this paper we move a preliminary step towards this goal. Namely, we work at the knowledge base for such a device.
De Falco I   +3 more
openaire   +1 more source

Interstitial glucose monitoring has acceptable clinical accuracy in juvenile dogs

Journal of the American Veterinary Medical Association, 2023
Abstract OBJECTIVE To compare the performance of an interstitial glucose monitor (IGM) versus a portable blood glucose monitor (PBGM) in sick juvenile dogs in a veterinary ICU. ANIMALS 16 client-owned dogs admitted to the university teaching hospital under 1 year of age with systemic illness.
Zsofia, Vigh   +4 more
openaire   +2 more sources

Prediction of Interstitial Glucose Level

IEEE Transactions on Information Technology in Biomedicine, 2012
Glucose is an important source of energy for cells. In clinical practice, we measure glucose level in blood and interstitial fluid. Each method has its pros and cons, and both levels correlate with each other. As the body tries to maintain the glucose level within a particular range to avoid adverse effects, it is desirable to predict future glucose ...
openaire   +2 more sources