Results 21 to 30 of about 23,888 (187)
Objectives Out‐of‐hospital cardiac arrest (OHCA) claims the lives of approximately 350,000 people in the United States each year. Resuscitative endovascular balloon occlusion of the aorta (REBOA) when used as an adjunct to advanced cardiac life support ...
James Daley +23 more
doaj +1 more source
Objective: to optimize preoperative preparation of patients with multifocal atherosclerosis and reduced baseline left ventricular ejection fraction for coronary bypass surgery, by providing a rationale for the use of mechanical and medical circulatory ...
E. V. Grigoryev +5 more
doaj +1 more source
1.6 DETRIMENTAL EFFECTS ON CAROTID PERFUSION OF INTRA-AORTIC BALLOON PUMP SUPPORT
Introduction: Intra-aortic balloon pumping is widely used to augment diastolic coronary perfusion. However, far less is known about its effects on other large arteries. In this study we assessed the effects of intra-arterial balloon pump pressure support
J.E. Davies +7 more
doaj +1 more source
In this study, a treatment method was assessed for the prevention and treatment of postpartum bleeding after combined surgery in patients having late pregnancy with the complication of acute Stanford type A aortic dissection.
Peng Mei +7 more
doaj +1 more source
Mechanical circulatory support with Impella in percutaneous coronary intervention: current status
In patients with, or at risk of, hemodynamic instability during percutaneous coronary intervention, maintaining perfusion of vital organs is crucial.
Baskaran Chandrasekar
doaj +1 more source
O balão intra-aórtico é um dispositivo de assistência circulatória mecânica utilizado nos casos de falência ventricular per-operatória. Neste estudo foram seguidos todos os pacientes submetidos a inserção de balão intra-aórtico durante 22 meses, no ...
Fabiano G. JUCÁ +4 more
doaj +1 more source
ABSTRACT Objectives To evaluate the feasibility and short‐term outcomes of transcatheter aortic valve replacement (TAVR) using balloon‐expandable Sapien valves in patients with prior endovascular aortic stent grafts. Methods We conducted a single‐center, retrospective study of 23 patients with prior endovascular aortic stent grafts who underwent TAVR ...
Iad Alhallak +8 more
wiley +1 more source
ABSTRACT Incomplete stent apposition at the proximal coronary artery may predispose to subtle guiding catheter–induced stent deformation, creating a gap between the stent and the vessel wall that facilitates inadvertent abluminal guidewire passage. We report a case in which balloon dilatation over an unrecognized abluminal guidewire resulted in severe ...
Yuto Abe +3 more
wiley +1 more source
Using mechanical support methods in patients with acute myocardial infarction
Objective. To evaluate the efficacy of mechanical support (extracorporeal membrane oxygenation + intra-aortic balloon pump) in patients with acute myocardial infarction complicated by heart failure.Results.
I. M. Kuzmina +5 more
doaj +1 more source
ABSTRACT Background Acquired aseptic intracardiac communications (AICCs) are rare but clinically relevant structural complications following transcatheter aortic valve implantation (TAVI), typically resulting from mechanical injury to the aortic annulus, interventricular septum, or adjacent structures.
Geza Fontos +6 more
wiley +1 more source

