Results 1 to 10 of about 16,786 (291)

Intra-Aortic Balloon Pump Rupture and Entrapment [PDF]

open access: yesCase Reports in Vascular Medicine, 2014
Intra-aortic balloon pump is used frequently to support a failing myocardium in cardiac patients. Due to the invasive nature of this device, usage is accompanied by consistent risk of complications. Balloon rupture, although it occurs rarely, may lead to
Artan Jahollari   +2 more
core   +5 more sources

Current management of patients with severe acute peripartum cardiomyopathy: practical guidance from the Heart Failure Association of the European Society of Cardiology Study Group on peripartum cardiomyopathy [PDF]

open access: yes, 2016
No abstract ...
Arrigo   +48 more
core   +10 more sources

How much of the intraaortic balloon volume is displaced toward the coronary circulation? [PDF]

open access: yes, 2010
This is a post-print version of the published article. Copyright @ 2010 The American Association for Thoracic Surgery.This article has been made available through the Brunel Open Access Publishing Fund.Objective: During intraaortic balloon inflation ...
Ashraf W. Khir   +28 more
core   +2 more sources

Descending aortic calcification increases renal dysfunction and in-hospital mortality in cardiac surgery patients with intraaortic balloon pump counterpulsation placed perioperatively : a case control study [PDF]

open access: yes, 2012
Introduction: Acute kidney injury (AKI) after cardiac surgery increases length of hospital stay and in-hospital mortality. A significant number of patients undergoing cardiac surgical procedures require perioperative intra-aortic balloon pump (IABP ...
Bingold, Tobias Michael   +9 more
core   +2 more sources

Intra-aortic balloon pump (ΙΑΒΡ): from the old trends and studies to the current “extended” indications of its use [PDF]

open access: yes, 2012
This report outlines the well defined indications of using IABP and also favours extending the indications of IABP use, to include not only “therapeutically” the aging unstable patients but also “prophylactically” patients with low EF or high ...
Alan Soo   +2 more
core   +1 more source

Management of lower limb ischaemia associated with the use of intra-aortic balloon pumps during cardiac surgery [PDF]

open access: yes, 1995
Objective:To audit the lower limb vascular complications associated with the use of an intraaortic balloon pump (IABP) on a cardiothoracic unit over a 12 month period.Design:Retrospective analysis.Setting:Regional university cardiothoracic unit.Patients ...
Jameson, J.S.   +3 more
core   +1 more source

Intraaortic balloon pumping for cardiac support: Trends in practice and outcome, 1968 to 1995 [PDF]

open access: yes, 1997
Objectives: A total of 4756 cases of intraaortic balloon pump support have been recorded at the Massachusetts General Hospital since the first clinical insertion for cardiogenic shock in 1968. This report describes the patterns of intraaortic balloon use
Akins, Cary W.   +8 more
core   +1 more source

Intraaortic balloon counterpulsation as a temporary support measure in decompensated critical aortic stenosis [PDF]

open access: yes, 1985
Intraaortic balloon counterpulsation was instituted in two adult patients whose condition was rapidly deteriorating because of critical decompensated valvular aortic stenosis.
Folland, Edward D.   +4 more
core   +1 more source

Intra‐aortic balloon pump: Looking at the other side [PDF]

open access: yesArtificial Organs, 2020
AbstractIntra‐aortic balloon pump has been the most commonly employed cardiac assist device in the past, although, in recent years, its use in cardiogenic shock has been questioned. The pathophysiology of the proximal part of the balloon has been well studied, whereas, hemodynamics and flow below the distal portion of the balloon have not been fully ...
Sandro Gelsomino, Monique M. J. de Jong
openaire   +4 more sources

Effects of intra-aortic balloon pump on cerebral blood flow during peripheral venoarterial extracorporeal membrane oxygenation support [PDF]

open access: yes, 2014
BACKGROUND: The addition of an intra-aortic balloon pump (IABP) during peripheral venoarterial extracorporeal membrane oxygenation (VA ECMO) support has been shown to improve coronary bypass graft flows and cardiac function in refractory cardiogenic ...
Chun-jing Jiang   +9 more
core   +1 more source

Home - About - Disclaimer - Privacy