Results 21 to 30 of about 374,471 (348)

Optic nerve sheath diameter: A novel way to monitor the brain

open access: yesJournal of Neuroanaesthesiology and Critical Care, 2017
Measurement and monitoring of intracranial pressure is pivotal in management of brain injured patients. As a rapid and easily done bed side measurement, ultrasonography of the optic nerve sheath diameter presents itself as a possible replacement of the ...
Seelora Sahu, Amlan Swain
doaj   +3 more sources

Noninvasive intracranial pressure real-time waveform analysis monitor during prostatectomy robotic surgery and Trendelenburg position: case report

open access: yesBrazilian Journal of Anesthesiology, 2021
Both robotic surgery and head-down tilt increase intracranial pressure by impairing venous blood outflow. Prostatectomy is commonly performed in elderly patients, who are more likely to develop postoperative cognitive disorders.
Gabriela Tognini Saba   +8 more
doaj   +1 more source

Targeted Perfusion Therapy in Spinal Cord Trauma. [PDF]

open access: yes, 2020
We review state-of-the-art monitoring techniques for acute, severe traumatic spinal cord injury (TSCI) to facilitate targeted perfusion of the injured cord rather than applying universal mean arterial pressure targets.
Papadopoulos, MC, Saadoun, S
core   +1 more source

Intracranial pressure monitoring

open access: yesJournal of Neuroanaesthesiology and Critical Care, 2015
Brain specific monitoring enables detection and prevention of secondary cerebral insults, especially in the injured brain, thereby preventing permanent neurological damage.
Mary Abraham, Vasudha Singhal
doaj   +1 more source

Wearable Intracranial Pressure Monitoring Sensor for Infants

open access: yesBiosensors, 2021
Monitoring of intracranial pressure (ICP) is important for patients at risk of raised ICP, which may indicate developing diseases in brains that can lead to brain damage or even death.
Baoyue Zhang   +4 more
doaj   +1 more source

Consensus-Based Management Protocol (CREVICE Protocol) for the Treatment of Severe Traumatic Brain Injury Based on Imaging and Clinical Examination for Use When Intracranial Pressure Monitoring Is Not Employed

open access: yesJournal of Neurotrauma, 2020
Globally, intracranial pressure (ICP) monitoring use in severe traumatic brain injury (sTBI) is inconsistent and susceptible to resource limitations and clinical philosophies.
R. Chesnut   +54 more
semanticscholar   +1 more source

Cerebral haemodynamics during experimental intracranial hypertension. [PDF]

open access: yes, 2016
Intracranial hypertension is a common final pathway in many acute neurological conditions. However, the cerebral haemodynamic response to acute intracranial hypertension is poorly understood.
Ainslie, Philip N   +8 more
core   +2 more sources

Routine intracranial pressure monitoring in a countryside university hospital

open access: yesBrazilian Neurosurgery, 2002
Intracranial pressure monitoring has become critical for the adequate management of patients with severe head injury in recent years. Several other recommendations for intracranial pressure monitoring have also been described, specially for patients with
Andrei Ferraz   +2 more
doaj   +1 more source

Modified “in-window” technique for decompressive craniotomy for severe brain injury [PDF]

open access: yesArchives of Biological Sciences, 2015
Increased intracranial pressure and decreased cerebral perfusion in patients with severe traumatic brain injury are associated with cerebral ischemia and poor outcome. Lowering intracranial pressure is one of the goals of treatment.
Jovanović Momir J.   +5 more
doaj   +1 more source

Measurement of Intraspinal Pressure After Spinal Cord Injury: Technical Note from the Injured Spinal Cord Pressure Evaluation Study. [PDF]

open access: yes, 2016
Intracranial pressure (ICP) is routinely measured in patients with severe traumatic brain injury (TBI). We describe a novel technique that allowed us to monitor intraspinal pressure (ISP) at the injury site in 14 patients who had severe acute traumatic ...
Bell, BA   +10 more
core   +1 more source

Home - About - Disclaimer - Privacy