Pneumatic retinopexy for displaced macular laceration from intraocular foreign body
PurposeTo report a case of macular laceration from intraocular foreign body (IOFB) treated with pneumatic retinopexy.ObservationsA 74 year old man sustained penetrating injury to his left globe with retained metallic intraocular foreign body (IOFB).
Coady, Patrick A. +5 more
core +1 more source
Relationship between types of ocular trauma in patients with intraocular foreign body and postoperative visual acuity [PDF]
OBJETIVO: Establecer la relación entre los tipos de traumas oculares en pacientes con cuerpo extraño intraocular y la agudeza visual postoperatoria. DISEÑO: Descriptivo, trasversal, retrospectivo.
Jaramillo Solá, José Agustín
core
Fourier transform spectroscopic identification of an intraocular foreign body. [PDF]
Bui AD +4 more
europepmc +1 more source
Siderosis bulbi as a consequence of a missed intraocular foreign body
We present a case of a 56-year-old man who suffered an injury to his right eye in June 2012. He presented to an emergency department, however, the presence of a penetrating injury and an intraocular foreign body was not identified.
Karl, David +2 more
core +1 more source
Objective To present a clinical case of successful removal of a foreign body from the anterior chamber angle following an explosive injury, accompanied by the restoration of visual functions.
Yelyzaveta Galytska +6 more
doaj +1 more source
Gonioscopy aided detection and scleral indentation assisted extraction of an occult intraocular foreign body from the ciliary sulcus. [PDF]
Naharwal A +3 more
europepmc +1 more source
A 28-mm intraocular foreign body removal: The vitreoretinal surgeon's dilemma. [PDF]
Gangwe A, Barwar G.
europepmc +1 more source
Pars plana vitrectomy in ocular injury with intraocular foreign body
PubMedID: 16385302Background: We evaluated 70 cases of ocular injuries with intraocular foreign bodies to determine the results of surgical management. Methods: The site of penetration was cornea in 58 (82.9%), sclera in 8 (11.4%), and limbus in 4 (5.7%)
Demircan N. +5 more
core +1 more source
Purpose of the work is to analyze the features of a reproducible model of a penetrating gunshot wound of the eyeball without an intraocular foreign body (type B open eye injury). Material and methods.
A. A. Kol’bin +2 more
doaj +1 more source
Retina-sparing suprachoroidal intraocular foreign body resulting in cyclodialysis cleft. [PDF]
Kane CP, Johnson TV, Sachdeva MM.
europepmc +1 more source

