Results 51 to 60 of about 676,006 (199)
This study investigated postoperative complications after surgery for medullary thyroid carcinoma (MTC) in Europe. Hypoparathyroidism, recurrent laryngeal nerve palsy and bleeding requiring reoperation occurred in 170 (26·2 per cent), 62 (13·7 per cent) and 17 (2·6 per cent) patients respectively.
D.‐J. van Beek +18 more
wiley +1 more source
This review brings together 20 publications describing 11 robotic system families developed for instrument handling, sterile‐package opening, supply delivery, and operating room logistics. Perception is becoming more capable through deep learning and language‐guided control, but autonomy remains limited, evidence is largely laboratory‐based, and no ...
Eugenia Mawuenya Akpo +4 more
wiley +1 more source
EndoTac presents a trocar‐compatible endoscopic vision‐based tactile sensor that uses a convex mirror to enlarge side‐facing tactile coverage during minimally invasive vessel palpation. Distorted tactile images are unwarped and processed by a learning model to estimate vascular deformation, enabling sensitive, spatially distributed tactile perception ...
Yupeng Wang +5 more
wiley +1 more source
The purpose of the present study was to determine ultrasound (US) arthrography diagnostic accuracy in patients with recurrent shoulder dislocation by comparing US arthrography and magnetic resonance arthrography (MRA) with intraoperative findings.
Muglia, Valdair F. +3 more
core +1 more source
Non‐invasively quantitative Raman imaging with stacking‐induced charge transfer‐enhanced Raman scattering (SICTERS) enables accurate measurement of concentrations and pharmacokinetic modeling of lymphatic transport of micelles in mice. This platform allows dynamic analysis of nanoparticle transport and underpins the design of effective lymph node ...
Yunlu Li +6 more
wiley +1 more source
Breast intraoperative electron radiation therapy (B-IOERT) can be used in clinical practice both as elective irradiation (partial breast irradiation – APBI) in low risk breast cancer patients, and as an anticipated boost. The procedure generally includes
Vidali Cristiana +10 more
doaj +1 more source
Extrusion‐based 3D printing of silicones and discrete electronic components are combined to create cortical implants for rodents that integrate thermal neuromodulation and electrical recording. Linked to an autonomous auxiliary driver unit, the system enables rapid, stable and localized hypothermia alongside ECoG recording.
Spencer Ryan Moore +6 more
wiley +1 more source
Objective At present, intraoperative ultrasound was widely used in spinal surgery. But there have been no reports on the use of intraoperative ultrasound in lateral decubitus position spinal surgery.
Bohan Li +11 more
doaj +1 more source
Registration Methods of Intraoperative Ultrasound and MR Images: A Review
Nowadays, registration of intraoperative ultrasound and MR images is an important issue in the neurosurgery and biopsy. In this study, we evaluate crucial parts of the intraoperative ultrasound such as neuronavigation system and registration methods, and
BİLGE, HASAN ŞAKİR, Mikaeili, Mahsa
core +1 more source
In this work, we present a bile‐based memristor hardware framework that enables direct, label‐free identification of cholelithiasis and gallbladder cancer at the device level. The Ag/bile/FTO memristor features stable resistive switching and disease‐specific electrical responses, providing a conceptual foundation for circuits and an integrated ERCP ...
Junming Zhu +17 more
wiley +1 more source

