Acute respiratory distress syndrome (ARDS) is a severe lung condition with limited treatments, often triggered by overactive endothelial cells (ECs). It is identified that macrophage‐derived secretory autophagosomes (MSAPs) exacerbate lung damage by activating EC function.
Xing‐xing Zhu+17 more
wiley +1 more source
Study on the effect of a cold environment on the quality of three video laryngoscopes: McGrath MAC, GlideScope Ranger, and Pentax Airway Scope [PDF]
Objective Several environmental factors influence the prehospital use of video laryngoscopes (VLs). For example, fogging of the VL lens can occur in cold environments, and the low temperature can cause the VLs to malfunction.
Jin Won Park, Hyuk Joong Choi
doaj +1 more source
Establishment of rat model for aspiration pneumonia and potential mechanisms
Aspiration pneumonia was induced in Sprague Dawley rats by intratracheal instillation of hydrochloric acid (HCl, 1.5 μL/g.wt, pH = 1) followed by lipopolysaccharide (LPS, 20 μg/g.wt) after 1 h. The model reproduced hallmark features of acute lung injury, including histological lung damage, microvascular dysfunction, inflammation, hypoxemia, and ...
Hanbing Hu+7 more
wiley +1 more source
Izazovi opstetricijske anestezije: otežana vizualizacija larinksa [PDF]
Obstetric anesthesia is one of the high risk subspecialties of anesthesia practice. Anesthesia related complications are the sixth leading cause of maternal mortality.
Başak Ceyda Orbey Meço+6 more
core +2 more sources
Grafts used to construct lung cancer animal models come from various sources, primarily cell lines, patient‐derived tumor tissues, and circulating tumor cells. Based on the sources of grafts and research objectives, lung cancer animal models can be categorized into several types: chemical‐induced models, orthotopic transplantation models, heterotopic ...
Zixuan Yang+7 more
wiley +1 more source
Comparison of the GlideScope and the McGrath method using vascular forceps and a tube exchanger in cases of simulated difficult airway intubation [PDF]
BackgroundA "difficult airway" can be simulated with an extrication collar, which restricts cervical motion and mouth opening. The purpose of this study is to compare the efficacy of the GlideScope and the McGrath in difficult airway simulation ...
Jae-Hang Shim+3 more
doaj +1 more source
Bronchopulmonary Dysplasia: Executive Summary of a Workshop [PDF]
Comment in Bronchopulmonary Dysplasia: The Ongoing Search for One Definition to Rule Them All. [J Pediatr. 2018] Midlife crisis? In its 50th year, BPD redefines itself.
Bancalari, Eduardo+17 more
core +1 more source
A mouse model of lung ischemia–reperfusion injury with reversible left hilar entrapment
A Novel Reversible Left Hilar Entrapment Model for Mouse Lung Ischemia‐Reperfusion Injury with Visual Tracheal Intubation and Live Knot Technique. Abstract Lung ischemia–reperfusion injury (LIRI), an acute lung injury syndrome triggered by lung transplantation or distal organ ischemia, has long been a difficult and hot issue in clinical research.
GuangDong Weng+4 more
wiley +1 more source
Adverse Effects of Intratracheal Intubation by Emergency Medicine Residents; a Cross-Sectional Study
Introduction: Airway management of patients is among the responsibilities of an emergency medicine specialist. To decrease the adverse effects of intubation, sufficient knowledge of the drugs used and proper skill in intratracheal intubation is needed ...
Iraj Golikhatir+3 more
doaj
Awake supraglottic airway guided flexible bronchoscopic intubation in patients with anticipated difficult airways: a case series and narrative review [PDF]
Awake intubation is indicated in difficult airways if attempts at securing the airway after induction of general anesthesia may lead to harm due to potential difficulties or failure in those attempts.
Wan Yen Lim, Patrick Wong
doaj +1 more source