Results 41 to 50 of about 3,101 (182)

Myths and methodologies: Optimising experimental rigour in heat adaptation research: Menstrual status classification and scheduling approaches

open access: yesExperimental Physiology, EarlyView.
Abstract Women remain underrepresented in thermal physiology research, particularly within studies examining physiological adaptation to hot environments. Among the limited research that includes female participants, few studies have appropriately classified menstrual status of their participants or rigorously accounted for ovarian hormone influences ...
Jessica A. Mee, Tessa R. Flood
wiley   +1 more source

Perception and use of reversible contraceptive methods in Germany: A social listening analysis

open access: yesWomen's Health, 2023
Background: With an increasing array of contraceptives in the market, it is important to understand how users perceive them and how their interests evolve over time.
Preetha Balakrishnan   +3 more
doaj   +1 more source

Immediate placement of intrauterine device after second‐trimester medical abortion—Secondary outcomes with one‐year follow‐up

open access: yesActa Obstetricia et Gynecologica Scandinavica, Volume 105, Issue 9, Page 1672-1679, September 2026.
Immediate intrauterine device placement after second‐trimester medical abortion was associated with a higher incidence of expulsion, lower use of IUD at 12 months, and lower acceptance compared with delayed placement. However, no significant increase in subsequent pregnancies or abortions was observed at the 12 month follow‐up.
Sara Hogmark   +4 more
wiley   +1 more source

Rectal translocation of intrauterine contraceptive device: A rare and infrequent occurrence

open access: yesSaudi Journal for Health Sciences, 2019
Displacement of copper intrauterine devices (IUDs) is not uncommon complication of these methods of contraception; many literatures have reported the translocation of IUDs to the peritoneum, bladder, and myometrium.
Muhammad Baffah Aminu   +2 more
doaj   +1 more source

Uncovering Modifiable Contributors to Depressive Symptoms During Antidepressant Prescription Renewal: A Primary Care Case Report

open access: yesClinical Case Reports, Volume 14, Issue 8, August 2026.
ABSTRACT Depressive symptoms in primary care often arise from a complex interplay of hormonal, biological, metabolic, psychosocial, and lifestyle factors. We present the case of a 41‐year‐old woman whose depressive symptoms began three months postpartum after her second pregnancy and persisted for approximately five years.
Leonora Muhadri, Hong Phan
wiley   +1 more source

Iron Physiology and Its Impact on Atopic Diseases: An EAACI Taskforce Report

open access: yesAllergy, Volume 81, Issue 8, Page 2675-2712, August 2026.
ABSTRACT Iron is essential for oxygen transport, energy metabolism, and immune regulation. Yet iron deficiency is the most common micronutrient disorder across all age groups, affecting nearly one quarter of the global population. Iron deficiency triggers nutritional immunity, a host defense mechanism that withholds and redistributes iron, contributing
Franziska Roth‐Walter   +19 more
wiley   +1 more source

Intrauterine deposition of calcium on copper-bearing intrauterine contraceptive devices. [PDF]

open access: yesBMJ, 1977
Copper-bearing intrauterine contraceptive devices (IUDs) removed after various times in utero were examined by scanning electron microscopy and x-ray microanalysis of the elements present. As time in utero increased these devices became increasingly calcified. This calcification may limit the release of copper from the devices and decrease the specific
C, Gosden, A, Ross, N B, Loudon
openaire   +2 more sources

Accuracy of next‐generation wireless skin temperature sensors during exercise–heat stress

open access: yesExperimental Physiology, Volume 111, Issue 8, Page 3463-3479, 1 August 2026.
Abstract Skin temperature is fundamental in characterising human thermoregulatory responses. Wired probes, although accurate, restrict movement and are impractical outside laboratory settings. The iButton (DS1922L; Maxim Integrated, USA) is a widely used wireless alternative but does not meet the precision recommended by ISO 9886 and permits only ...
Aaron J. E. Bach   +6 more
wiley   +1 more source

Use of frameless intrauterine devices and systems in young nulliparous and adolescent women: results of a multicenter study

open access: yesInternational Journal of Women's Health, 2014
Dirk Wildemeersch,1 Sohela Jandi,2 Ansgar Pett,2 Kilian Nolte,3 Thomas Hasskamp,4 Marc Vrijens5 1Gynecological Outpatient Clinic and IUD Training Center, Ghent, Belgium; 2Gynecological Outpatient Clinic, Berlin, 3Gynecological Outpatient Clinic, Uetze ...
Wildemeersch D   +5 more
doaj  

Biological evaluation of the copper/low-density polyethylene nanocomposite intrauterine device. [PDF]

open access: yesPLoS ONE, 2013
Devices and materials intended for clinical applications as medical and implant devices should be evaluated to determine their biocompatibility in physiological systems.
Li-Xia Hu   +9 more
doaj   +1 more source

Home - About - Disclaimer - Privacy