Results 111 to 120 of about 4,192,465 (140)
Inverted internal limiting membrane flap technique for very large macular hole
To assess the anatomical and visual outcome of idiopathic macular holes greater than 1000 µm using the inverted internal limiting membrane flap technique.This retrospective case series included 5 eyes of 5 patients with idiopathic macular hole with base diameter greater than 1000 µm who underwent inverted internal limiting membrane flap technique along
Raja Narayanan
exaly +3 more sources
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Modified inverted internal limiting membrane flap technique for macular hole closure
Japanese Journal of Ophthalmology, 2022To investigate the efficacy of modified internal limiting membrane (ILM) flap technique combined with vitreous surgery for treating macular holes and examine the outcomes in visual function and anatomic macular hole closure.Retrospective, observational.Between July 1, 2015, and October 1, 2019, the modified inverted ILM flap technique combined with ...
Sayaka, Kakehi +3 more
openaire +2 more sources
Macular hole reopening after inverted internal limiting membrane flap
Journal of Case Reports and Images in Ophthalmology, 2022Introduction: Here, we present a case of macular hole (MH) reopening after an initial successful closure with an inverted internal limiting membrane (ILM) flap procedure. Case Report: The patient was a 72-year-old Hispanic male who presented with decreased vision in the right eye who was found to have a 431 μm, full-thickness ...
Hossein Ameri +2 more
openaire +1 more source
Retina, 2015
To determine if reducing the area of internal limiting membrane (ILM) peeling in the inverted ILM flap technique results in satisfactory outcomes for the repair of large Stage IV idiopathic macular holes.Prospective comparative interventional study of 87 consecutive eyes. Participants were randomized into two treatment groups.
Zofia, Michalewska +4 more
openaire +2 more sources
To determine if reducing the area of internal limiting membrane (ILM) peeling in the inverted ILM flap technique results in satisfactory outcomes for the repair of large Stage IV idiopathic macular holes.Prospective comparative interventional study of 87 consecutive eyes. Participants were randomized into two treatment groups.
Zofia, Michalewska +4 more
openaire +2 more sources
MECHANISM OF “FLAP CLOSURE” AFTER THE INVERTED INTERNAL LIMITING MEMBRANE FLAP TECHNIQUE
Retina, 2018Purpose: Recent studies described that in approximately 14% to 16% of cases of macular holes treated with the inverted internal limiting membrane flap technique, the hole was closed only by a thin layer of inverted internal limiting membrane—“flap closure.” The aim of this article was to describe the functional and anatomical ...
Karolina, Bonińska +2 more
openaire +2 more sources
Inverted Internal Limiting Membrane Flap Technique for Large Macular Holes
Ophthalmology, 2010Large macular holes usually have an increased risk of surgical failure. Up to 44% of large macular holes remain open after 1 surgery. Another 19% to 39% of macular holes are flat-open after surgery. Flat-open macular holes are associated with limited visual acuity.
Zofia, Michalewska +3 more
openaire +2 more sources
Mechanism of ‘Flap Closure’ after the inverted internal limiting membrane flap technique
Acta Ophthalmologica, 2016Purpose4 macular hole closure types are known: U‐type, V‐ type, irregular and flat open. After the inverted ILM flap technique some macular holes are covered only with a thin layer of the inverted ILM flap shortly after surgery (flap closure). The aim of this paper is to describe functional and anatomical results in eyes closed with ‘flap closure ...
Z. Michalewska +3 more
openaire +1 more source
INVERTED INTERNAL LIMITING MEMBRANE FLAP TECHNIQUES AND OUTER RETINAL LAYER STRUCTURES
Retina, 2020Purpose: To examine the influence of the inverted flap (IF) internal limiting membrane (ILM) technique in macular hole (MH) closure on outer retinal layers after MH surgery. Methods: Retrospective study.
Mun Yueh, Faria +5 more
openaire +2 more sources
European Journal of Ophthalmology, 2019
Purpose: To compare the functional, anatomical, and morphological results of conventional internal limiting membrane peeling versus temporal inverted internal limiting membrane flap technique for the treatment of macular holes larger than 400 μm. Design:
Remzi Avci +2 more
openaire +2 more sources
Purpose: To compare the functional, anatomical, and morphological results of conventional internal limiting membrane peeling versus temporal inverted internal limiting membrane flap technique for the treatment of macular holes larger than 400 μm. Design:
Remzi Avci +2 more
openaire +2 more sources
Retina, 2022
Purpose: To evaluate the anatomical and functional outcomes of internal limiting membrane (ILM) peeling and the inverted ILM flap technique for rhegmatogenous retinal detachment coexisting with macular hole. Methods: This retrospective study evaluated the medical records of 79 eyes ...
Xujia, Liu +8 more
openaire +2 more sources
Purpose: To evaluate the anatomical and functional outcomes of internal limiting membrane (ILM) peeling and the inverted ILM flap technique for rhegmatogenous retinal detachment coexisting with macular hole. Methods: This retrospective study evaluated the medical records of 79 eyes ...
Xujia, Liu +8 more
openaire +2 more sources