Results 1 to 10 of about 39,620 (188)
Monte‐Carlo simulation of a thick lens IOL power calculation [PDF]
Background The purpose of this Monte-Carlo study is to investigate the effect of using a thick lens model instead of a thin lens model for the intraocular lens (IOL) on the resulting refraction at the spectacle plane and on the ocular magnification ...
Hoffmann, Peter +13 more
core +3 more sources
The repeatability results of IOL-X, IOL-Y, and IOL-D using different statistical analysis methods.
IOL = intraocular lens; IOL-X = IOL decentration in the x-axis; IOL-Y = IOL decentration in the y-axis; IOL-D = IOL decentration in the distance; Mean SD = mean standard deviation; ICC = intraclass correlation coefficients; 95% CI = 95% confidence ...
Qinmei Wang (132105) +11 more
core +1 more source
Long-Term Outcome and Complications of IOL-Exchange
David A Märker,1 Viola Radeck,1 Teresa Barth,1 Horst Helbig,1 Nicolas CD Scherer1,2 1Department of Ophthalmology, Universitätsklinikum Regensburg, University of Regensburg, Regensburg, Bavaria, Germany; 2Department of Ophthalmology, Ludwig-Maximilians ...
Märker DA +4 more
core
The repeatability results of C-IOL-X, C-IOL-Y, C-IOL-D using different statistical analysis methods.
IOL = intraocular lens; C-IOL-X = Anterior capsulorhexis-IOL decentration in the x-axis; C-IOL-Y = Anterior capsulorhexis-IOL decentration in the y-axis; C-IOL-D = Anterior capsulorhexis-IOL decentration in the distance; Mean SD = mean standard deviation;
Qinmei Wang (132105) +11 more
core +1 more source
Oxygen‐tolerant photoinduced electron/energy transfer reversible addition–fragmentation chain transfer (PET‐RAFT) polymerization enables the controlled radical ring‐opening (rROP) copolymerization of cyclic dithiothreitol (cDTT) with less‐activated vinyl monomers, affording degradable polymers with predictable molecular weights, low dispersities, and ...
Alessandro Magro +5 more
wiley +1 more source
The rising tide: Trends in induction of labor at term over a 5‐year period at a single centre
Abstract Objective Induction of labor (IOL) is a controversial topic in contemporary obstetric practice, with some suggesting that the increase in elective induction (eIOL) as a potential contributor to increasing cesarean delivery (CD) rates. The objectives of this single‐center study were to examine the rates of IOL, trends in indications for IOL ...
Sarah M. Nicholson +7 more
wiley +1 more source
Comparison of IOL – Master and Ultrasound Biometry in Preoperative Intra Ocular Lens (IOL) Power Calculation [PDF]
Postoperative refractive outcome largely depends on the accuracy of calculating power of implanted IOL. Lens power calculation can be done by conventional ultrasound biometry and partial coherence laser interferometry (IOL Master).
Škara Kolega, Marija +4 more
core +1 more source
myo‐Inositol's role in laying hens’ active gastrointestinal microbiota: a strain comparison
Abstract BACKGROUND myo‐Inositol (MI) is a cyclitol involved in cellular metabolism and phytate degradation, yet its influence on the gastrointestinal tract (GIT) microbiota of laying hens remains poorly understood. This study investigated the effects of graded dietary MI supplementation on the active GIT microbial communities of two commercial laying ...
Naomi Sarpong +4 more
wiley +1 more source
ABSTRACT Objective To evaluate the long‐term impact of a structured, multidisciplinary CS reduction strategy in a high‐complexity Italian hospital. Design Retrospective ecological time‐trend study. Setting Tertiary obstetric care Italian centre. Sample 28 577 deliveries, ≥ 22 weeks' gestation, from 2014 to 2024 were analysed.
Stefania Fieni +4 more
wiley +1 more source

