Results 21 to 30 of about 561,896 (299)

Potentiometric Determination of Cyclizine by a PVC membrane Sensor

open access: yesInternational Journal of Electrochemical Science, 2013
Potentiometric determination of Cyclizine was performed by a potentiometric PVC membrane sensor. Sodium tetraphenyl borate was used for the preparation of the sensing element used in the membrane.
Mohammad Reza Ganjali   +3 more
doaj   +1 more source

Complexation of Oppositely Charged Polyelectrolytes:  Effect of Ion Pair Formation [PDF]

open access: yesMacromolecules, 2004
Complexation in symmetric solutions of oppositely charged polyelectrolytes is studied theoretically. We include polyion crosslinking due to formation of thermoreversible ionic pairs. The electrostatic free energy is calculated within the Random Phase Approximation taking into account the structure of thermoreversible polyion clusters. The degree of ion
Kudlay, Alexander   +2 more
openaire   +2 more sources

Extractive Spectrophotometric Determination of Malathion in Environmental Samples Using Gention Violet

open access: yesE-Journal of Chemistry, 2005
A new simple and selective spectrophotometric method is developed for the determination of malathion by using Gention violet is described. The method was based on the alkaline hydrolysis of malathion in presence of sodium ethoxide to form sodium dimethyl
K. M. Reddy   +4 more
doaj   +1 more source

Di-μ-chlorido-bis(chlorido{8-[2-(dimethylamino)ethylamino]quinoline}cadmium) ethanol monosolvate

open access: yesIUCrData, 2021
The title solvated bimetallic complex, [Cd2Cl4(C13H17N3)2]·C2H5OH, comprises two Cd2+ metal ions linked by a pair of μ2 Cl− ions. The coordination sphere around each Cd2+ ion is completed by three N atoms of a tridentate 8-[2-(dimethylamino)ethylamino ...
Abdul-Razak H. Al-Sudani   +2 more
doaj   +1 more source

MWCNTs Based Carbon Paste and PVC Membrane Potentiometric Electrodes for Monitoring of Bupropion Hydrochloride

open access: yesInternational Journal of Electrochemical Science, 2012
Bupropion hydrochloride, active component of an antidepressant drug, was determined in the pharmaceutical formulation by two new bupropion potentiometric sensors.
M.R. Ganjali, F. Mizani, P. Norouzi
doaj   +1 more source

Characterization of a mixed-reagent ion-pair complex

open access: yesInternational Journal of Research in Engineering and Innovation, 2023
A method has been proposed for the determination of drug containing amino group phenylephrine hydrochloride (PHP) in pharmaceutical dosage forms. The method is based on the ion pair reaction of this drug with reagent (egg yellow) in alkaline medium to give intense orange colored product (λmax at 470 nm of PHP) with molar absorptivity values of 1.67 ...
openaire   +1 more source

Bis(N,N-diethyl-4-methyl-4-piperazine-1-carboxamide) tetrakis(isothiocyanato-κN)cobalt(II), a model compound for the blue color developed in the Scott test

open access: yesActa Crystallographica Section E: Crystallographic Communications, 2023
The complex, bis(N,N-diethyl-4-methyl-4-piperazine-1-carboxamide) tetrakis(isothiocyanato-κN)cobalt(II) (N,N-diethyl-4-methyl-4-piperazine-1-carboxamide = diethylcarbamazine), (C10H22N3O)2[Co(NCS)4], is presented.
Allen G. Oliver   +3 more
doaj   +1 more source

Novel PVC Membrane Selective Electrode for the Determination of Clozapine in Pharmaceutical Preparations

open access: yesInternational Journal of Electrochemical Science, 2009
Novel clozapine ion selective electrode was fabricated, characterized and used for determination of clozapine in its pharmaceutical formulations. The proposed sensor incorporated clozapine phosphotungstate ion pair complex as electroactive material in ...
Amirh S. Al Attas
doaj   +1 more source

Towards an analytical theory for charged hard spheres [PDF]

open access: yes, 2007
Ion mixtures require an exclusion core to avoid collapse. The Debye Hueckel theory, where ions are point charges, is accurate only in the limit of infinite dilution. The MSA is the embedding of hard cores into DH, is valid for higher densities.
Blum, L., Veloz, D. V. Perez
core   +4 more sources

A Highly Sensitive Impedimetric Metamitron Microsensor Based on All-Solid-State Membrane Using a New Ion-Pair Complex, [3,3′-Co(1,2-closo-C2B9H11)2][C10H11ON4]+

open access: yesProceedings, 2018
An all-solid-state impedimetric microsensor based on impedimetric measurements for detecting the herbicide metamitron (MM) is reported in the present work. For this purpose, a novel metamitron ionophore has been prepared. It was based on the isolation of
Zakaria Ayroud   +8 more
doaj   +1 more source