Potentiometry - Theoretical Principles and Analytical Applications [PDF]
Potentiometry is an electroanalytical technique that is usually employed to analyze the concentration of ionic solutes in aqueous and non-aqueous media.
Gulaboski, Rubin
core +2 more sources
Physio-mechanical Materials Testing Using Scanning Contact Potentiometry Method [PDF]
To study the processes of forming and growing embryonic fatigue cracks in steel EI-847 when tested under a uniaxial tension at constant load; adapting the method of scanning contact potentiometry using the INSTRON-5982 machine. The embryo was detected on
Osintsev, A V +9 more
core +1 more source
Potentiometry, chemical equilibria, and flow injection analysis—three important topics taught with one experimental setup [PDF]
In general, concepts such as chemical equilibria and classical analytical chemistry, as well as instrumental methods such as potentiometry and flow injection analysis (FIA), are taught separately in the curricula of chemistry-related degree programs ...
Kahlert, Heike +2 more
core +1 more source
Flexible Wearable Sensors for Site‐Specific Noninvasive Health Monitoring
Site‐specific design transforms flexible wearable biosensors from generic sensing devices into anatomically adapted health‐monitoring platforms. By linking local physiological and biochemical signals with tailored materials, sensing mechanisms, multimodal integration, and artificial intelligence, wearable systems are advancing toward more reliable ...
Yuqing Tang +6 more
wiley +1 more source
Scanning tunneling potentiometry of semiconductor junctions
A method for performing scanning tunneling potentiometry of semiconductor heterojunctions is described. The method yields a direct measure of the electrostatic potential distribution across the interface, with microscopic resolution.
Randall Feenstra (3885121) +3 more
core +1 more source
This work proposes and validates a method for measuring nitrate concentration with printed, solid‐state ion‐selective electrodes that does not require a stable reference electrode. The approach uses brief, localized heating pulses to generate a concentration‐dependent voltage response that is drift‐resilient and log‐linear from 0.1 to 100 mm, while ...
Lucas Lahann +2 more
wiley +1 more source
A Trans‐1,2‐Diphenyl‐Substituted EDTA Platform for High‐Relaxivity Mn(II) MRI Probes
Symmetric diphenyl substitution of the EDTA backbone enhances the rigidity of the Mn(II) complex and enables strong multisite interactions, providing a versatile platform for further functionalisation and conjugation towards high‐performance Mn(II)‐based MRI contrast agents.
Federico Forgione +7 more
wiley +1 more source
Comparative analysis of ionization constants determination using spectrophotometry and potentiometry: 3-aminobenzoic acid, 1,3,5-benzenetricarboxylic acid and tyrosine [PDF]
The ionization constant (usually expressed in logarithmic form, pKa) is important physicochemical parameter which is used to characterize the acid-base chemistry of a compound.
Marković, Olivera S. +3 more
core +4 more sources
Implantable electrochemical sensors for continuous blood monitoring
Implantable electrochemical sensors enable direct, in situ, and continuous blood monitoring, shifting diagnosis from population‐based averages to dynamic, individualized analysis. This review systematically examines the influence of the unique blood properties on sensor design.
Kuangyi Zou +3 more
wiley +1 more source
Assessing antioxidant activity of tea extracts and some of chemicals using voltammetry and potentiometry [PDF]
The comparison of antioxidant activity of tea extracts and some chemicals was conducted by independent methods: voltammetry and potentiometry. Except for few cases, we showed satisfactory agreement between test substances activity rows obtained by two ...
Valentina Batalova +5 more
core +2 more sources