Results 21 to 30 of about 14,868 (222)

Whole virus detection using aptamers and paper‐based sensor potentiometry

open access: yesMedical Devices & Sensors, 2020
Paper‐based sensors, microfluidic platforms and electronics have attracted attention in the past couple of decades because they are flexible, can be recycled easily, environmentally friendly and inexpensive.
S. Dolai, M. Tabib-Azar
semanticscholar   +1 more source

Chemically Induced pH Perturbations for Analyzing Biological Barriers Using Ion-Sensitive Field-Effect Transistors

open access: yesSensors, 2021
Potentiometric pH measurements have long been used for the bioanalysis of biofluids, tissues, and cells. A glass pH electrode and ion-sensitive field-effect transistor (ISFET) can measure the time course of pH changes in a microenvironment as a result of
Tatsuro Goda
doaj   +1 more source

Potentiometry - Theoretical Principles and Analytical Applications [PDF]

open access: yes, 2021
Potentiometry is an electroanalytical technique that is usually employed to analyze the concentration of ionic solutes in aqueous and non-aqueous media.
Gulaboski, Rubin
core  

Dissolution périodique du nickel dans l'acide nitrique en présence de chlorures

open access: yesCHIMIA, 1975
In the presence of Cl-, nickel dissolves periodically in HNO3 for normalities between 9 < N < 17. This phenomenon is investigated by potentiometry and thermometry.
Vincent J. Farage   +2 more
doaj   +1 more source

Impact of the Covering Vegetable Oil on the Sensory Profile of Canned Tuna of Katsuwonus pelamis Species and Tuna’s Taste Evaluation Using an Electronic Tongue

open access: yesChemosensors, 2022
The impact of the covering vegetable oil (sunflower oil, refined olive oil and extra virgin olive oil, EVOO) on the physicochemical and sensory profiles of canned tuna (Katsuwonus pelamis species) was evaluated, using analytical techniques and a sensory ...
Nuno Ferreiro   +6 more
doaj   +1 more source

NO2 Detection Using Microcantilever Based Potentiometry

open access: yesSensors, 2008
A highly sensitive and novel sensor platform for gases and volatile chemicals using microcantilever based potentiometry is reported. A resonant cantilever is used to detect the changes in surface work functions of functionalized substrates caused by ...
Goutam Koley, Muhammad Qazi
doaj   +1 more source

Potentiometric Determination of Maprotiline Hydrochloride in Pharmaceutical and Biological Matrices Using a Novel Modified Carbon Paste Electrode

open access: yesSensors, 2022
Potentiometry with membrane selective electrodes is preferable for measuring the various constituents of pharmaceuticals. In this work, carbon paste electrodes (CPE) were prepared, modified, and tested for the determination of maprotiline hydrochloride ...
Josip Radić   +3 more
doaj   +1 more source

Uses of nitrate ion sensitive electrodes

open access: yesEclética Química, 2018
Some models of ion-selective electrodes (ISE) and other methods have been elaborated, to quantify nitrate levels in environmental samples (water, fruits, vegetables and others), using direct ...
Rubén DEL TÓRO DÉNIS   +3 more
doaj   +1 more source

Voltammetric Ion Sensing with Ionophore-Based Ion-Selective Electrodes Containing Internal Aqueous Solution, Improving Lifetime of Sensors

open access: yesMembranes, 2022
The possibility of voltammetric ion sensing is demonstrated, for the first time, for ion-selective electrodes (ISEs) containing an internal aqueous solution. ISEs selective to calcium, lithium and potassium ions are used as model systems.
Valentina Keresten, Konstantin Mikhelson
doaj   +1 more source

Label-Free Monitoring of Histone Acetylation Using Aptamer-Functionalized Field-Effect Transistor and Quartz Crystal Microbalance Sensors

open access: yesMicromachines, 2020
Chemical and enzymatic modifications of amino acid residues in protein after translation contain rich information about physiological conditions and diseases.
Tatsuro Goda, Yuji Miyahara
doaj   +1 more source

Home - About - Disclaimer - Privacy