Results 191 to 200 of about 7,880 (221)
Some of the next articles are maybe not open access.

Transversal Modulation Ion Mobility Spectrometry (IMS) Coupled with Mass Spectrometry (MS): Exploring the IMS-IMS-MS Possibilities of the Instrument

Analytical Chemistry, 2015
A prototype is introduced based on the transversal modulation ion mobility spectrometry (TMIMS) technique, which provides a continuous output of mobility-selected ions, greatly easing the synchronization between different analyzing stages. In the new architecture, two stages of filtration are used to drastically reduce the background produced by one ...
G, Vidal-de-Miguel   +3 more
openaire   +2 more sources

Influence of Reduced Field Strength on Product Ion Formation in High Kinetic Energy Ion Mobility Spectrometry (HiKE-IMS)

Journal of the American Society for Mass Spectrometry, 2021
Classical ion mobility spectrometers (IMS) operated at ambient pressure, often use atmospheric pressure chemical ionization (APCI) sources to ionize organic compounds. In APCI, reactant ions ionize neutral analyte molecules via gas-phase ion–molecule reactions. The positively charged reactant ions in purified, dry air are H3O+, NO+, and O2+•.
Christoph Schaefer   +2 more
exaly   +3 more sources

An ion mobility spectrometry/mass spectrometry (IMS/MS) study of the site of protonation in anilines

Structural Chemistry, 1990
Ion mobility spectrometry (IMS) and IMS/MS techniques were used to differentiate between nitrogenprotonated and carbon-protonated anilines, both of which coexist under the conditions of the IMS. Analysis of the results led to the conclusion that the former species had lower mobilities than the latter. This was attributed mainly to charge delocalization
Zeev Karpas   +2 more
openaire   +1 more source

Analyzing Positive Reactant Ions in High Kinetic Energy Ion Mobility Spectrometry (HiKE-IMS) by HiKE-IMS–MS

Journal of the American Society for Mass Spectrometry, 2020
In contrast to classical ion mobility spectrometers (IMS) operating at ambient pressure, the high kinetic energy ion mobility spectrometer (HiKE-IMS) is operated at reduced pressures between 10-40 mbar. In HiKE-IMS, ions are generated in a reaction region before they are separated in a drift region.
Maria Allers   +7 more
openaire   +2 more sources

Validation of an ion mobility spectrometry (IMS) method for the detection of heroin and cocaine on incriminated material

Forensic Science International, 2008
The validation of a qualitative ion mobility spectrometry (IMS) procedure for the detection of trace amounts of heroin and cocaine on incriminated material using a vacuum cleaner for sampling is presented. The limit of detection, the limit of decision, selectivity and robustness were determined.
Franz E, Dussy   +5 more
exaly   +3 more sources

Influence of Sample Gas Humidity on Product Ion Formation in High Kinetic Energy Ion Mobility Spectrometry (HiKE-IMS)

Journal of the American Society for Mass Spectrometry, 2022
High Kinetic Energy Ion Mobility Spectrometers (HiKE-IMS) chemically ionize gaseous samples via reactant ions and separate the generated ions by their motion in a neutral gas under the influence of an electric field. Operation at reduced pressures of 10–40 mbar allows for reaching high reduced electric field strengths (E/N) of up to 120 Td.
Christoph Schaefer   +3 more
openaire   +2 more sources

Examination of some organic explosives by ion mobility spectrometry (IMS)

2005
The increase in terrorist activities committed using explosives in recent years has generated the need for improved analytical methods that can accurately and quickly identify explosives and their residues. In this study such an analytical method is evaluated. In the first phase of the study, standard solutions and a standard mixture solution of TNT (2,
Seven, E, Calimli, A, Koyuncu, H
openaire   +2 more sources

Detection of tetrahydrocannabinol residues on hands by ion-mobility spectrometry (IMS). Correlation of IMS data with saliva analysis

Analytical and Bioanalytical Chemistry, 2015
Ion-mobility spectroscopy (IMS) was evaluated as a high-throughput, cheap, and efficient analytical tool for detecting residues of tetrahydrocannabinol (THC) on hands. Regarding the usefulness of hand residues as potential samples for determining THC handling and abuse, we studied the correlation between data obtained from cannabis consumers who were ...
Saskia, Sonnberg   +3 more
openaire   +2 more sources

Multicapillary ion mobility spectrometry (MCC-IMS) for early identification of bacteria in vitro

Respiratory Infections, 2017
Introduction: Early differentiation of bacterial species is crucial especially in the scope of emerging multiresistant strains. Conventional diagnosis takes about 3 working days even Maldi-TOF requires a preculture and is normally not available in less than 12 – 24 hours. During growth bacteria produce specific volatile compounds (VOC).
Claus Steppert   +6 more
openaire   +1 more source

Transversal Modulation Ion Mobility Spectrometry (TM-IMS), A New Mobility Filter Overcoming Turbulence Related Limitations

Analytical Chemistry, 2012
The analysis of ions according to their mobility is a technique that is attracting increasing interest. The new technology presented here, which we have termed Transversal Modulation Ion Mobility Spectrometry (TM-IMS), utilizes only electric fields, operates at atmospheric pressure, produces a continuous output of mobility selected ions (according to ...
G, Vidal-de-Miguel, M, Macía, J, Cuevas
openaire   +2 more sources

Home - About - Disclaimer - Privacy