Results 51 to 60 of about 2,084 (194)

A cost-effectiveness analysis of iStent inject combined with phacoemulsification cataract surgery in patients with mild-to-moderate open-angle glaucoma in France.

open access: yesPLoS ONE, 2021
ObjectiveTo investigate the cost-effectiveness of implementing iStent inject trabecular bypass stent (TBS) in conjunction with cataract surgery (Cat Sx) in patients with mild-to-moderate glaucoma from a societal perspective in France.
Kaspar Nieland   +7 more
doaj   +2 more sources

Efficacy of Selective Laser Trabeculoplasty after iStent Implantation in Primary Open-Angle Glaucoma

open access: yes, 2021
iStent implantation is thought to augment the trabecular outflow channel in the anterior segment of the eye. We hypothesized that iStent with subsequent selective laser trabeculoplasty (SLT) would better control the intraocular pressure (IOP) compared to
Patrice M Hicks   +4 more
core   +1 more source

Innovative Drug Delivery Systems for the Treatment of Glaucoma

open access: yesMedComm – Biomaterials and Applications, Volume 5, Issue 2, June 2026.
This review aims to provide a comprehensive overview of current topical drug delivery strategies for ocular hypotensive agents in glaucoma therapy. Additionally, it discusses the potential impact of emerging nanotechnological and biomaterial‐based systems in shaping the future of ophthalmic drug delivery, with an emphasis on enhancing efficacy, safety,
Jing Chu   +9 more
wiley   +1 more source

Clinical outcomes of the PAUL glaucoma implant in primary open‐angle and pseudoexfoliative glaucoma eyes after failed glaucoma surgeries

open access: yesActa Ophthalmologica, Volume 104, Issue 2, Page e183-e190, March 2026.
Abstract Purpose This study assesses the PAUL® glaucoma implant (PGI) in primary open angle glaucoma (POAG) and pseudoexfoliative glaucoma (PEXG) after failed glaucoma surgery. Given PEXG's more aggressive nature, limited research exists on PGI outcomes in this subgroup. This study aims to compare PGI's efficacy and safety in both conditions. Methods A
Constance Liegl   +8 more
wiley   +1 more source

Preliminary Findings in Cataract Surgery Using a Digital Microscope Platform With Infrared Illumination

open access: yesJournal of Ophthalmology, Volume 2026, Issue 1, 2026.
Purpose To evaluate the safety and efficacy of infrared (IR) illumination using a digital microscope platform to perform uncomplicated cataract surgery. Methods A retrospective case series of 39 eyes (33 patients) that underwent cataract surgery under topical anesthesia.
Brady Wortz   +5 more
wiley   +1 more source

Association Between Prior Selective Laser Trabeculoplasty and Phaco‐iStent Inject Efficacy

open access: yesClinical &Experimental Ophthalmology, Volume 53, Issue 9, Page 1148-1155, December 2025.
ABSTRACT Background To evaluate the association between prior selective laser trabeculoplasty (SLT) on intraocular pressure (IOP) lowering efficacy of phacoemulsification combined with iStent inject (phaco‐iStent). Methods Retrospective study of 1550 eyes of 1023 patients with and without prior SLT that underwent phaco‐iStent.
Jeremy C. K. Tan   +8 more
wiley   +1 more source

Minimally Invasive Glaucoma Surgery: Is It Here to Stay?

open access: yesClinical &Experimental Ophthalmology, Volume 53, Issue 8, Page 1025-1038, November 2025.
ABSTRACT The advent of minimally invasive glaucoma surgery (MIGS) has expanded the treatment options available for glaucoma by providing options for reducing intraocular pressure without the serious complication profile associated with incisional glaucoma surgery.
Neeranjali Jain, Jennifer C. Fan Gaskin
wiley   +1 more source

Minimally Invasive Glaucoma Surgery Procedure in the Human Eye. A Fluid Structure Interaction Study

open access: yesInternational Journal for Numerical Methods in Biomedical Engineering, Volume 41, Issue 7, July 2025.
The implantation of a microstent for glaucoma surgery has been successfully simulated for the first time. A Fluid‐Structure Interaction (FSI) simulation is introduced to model aqueous humor flow dynamics post‐surgery, enabling a detailed analysis of the microstent's interaction with ocular tissues and fluids.
Elena Redaelli   +4 more
wiley   +1 more source

Reinterventions After PreserFlo Implantation: A Report on Results in Clinical Practice

open access: yesJournal of Ophthalmology, Volume 2025, Issue 1, 2025.
Background The PreserFlo MicroShunt is an effective surgical procedure for intraocular pressure (IOP) control in glaucoma. This study focuses on the rate of reinterventions after PreserFlo implantation, as well as exploring possible risk factors for reintervention. Methods This retrospective study included all patients undergoing PreserFlo implantation
Beatriz Puerto   +6 more
wiley   +1 more source

Exploring Glaucoma: From Pathogenesis to Emerging Diagnostic and Management Strategies

open access: yesJournal of Ophthalmology, Volume 2025, Issue 1, 2025.
Glaucoma is a leading cause of irreversible blindness globally, affecting millions of individuals. It encompasses a group of progressive optic neuropathies characterized by retinal ganglion cell loss and visual field deterioration, often associated with elevated intraocular pressure.
Rajesh Kumar Goit, Nilufer Yesilirmak
wiley   +1 more source

Home - About - Disclaimer - Privacy