Results 41 to 50 of about 20,421 (195)
Objectives To compare the efficacy and safety of two Schlemm’s canal-based microinvasive glaucoma surgery (MIGS) devices, the Hydrus Microstent and the iStent Trabecular Bypass combined with phacoemulsification for treatment of open-angle glaucoma.Design
Xiaoyu Wang +4 more
doaj +1 more source
Glaukos iStent inject® Trabecular Micro-Bypass Implantation Associated with Cataract Surgery in Patients with Coexisting Cataract and Open-Angle Glaucoma or Ocular Hypertension: A Long-Term Study [PDF]
Purpose. To evaluate the long-term efficacy and safety of the iStent inject device (Glaukos Corporation, Laguna Hills, CA) combined with phacoemulsification in patients with coexistent cataract and open-angle glaucoma or ocular hypertension (OHT ...
Arriola Villalobos, Pedro +5 more
core +4 more sources
Use of iStent as a Standalone Operation in Patients with Open-Angle Glaucoma
Purpose. The iStent provides a direct pathway for aqueous outflow from the anterior chamber to Schlemm’s canal in patients with open-angle glaucoma (OAG).
Yu-Yen Chen +3 more
doaj +1 more source
Ricardo Augusto Paletta Guedes,1 Daniela Marcelo Gravina,1 Vanessa Maria Paletta Guedes,1 Alfredo Chaoubah2 1Glaucoma Department, Paletta Guedes Eye Institute, Juiz de Fora, MG, Brazil; 2Statistics Department, Federal University of Juiz De Fora, Juiz de ...
Paletta Guedes RA +3 more
doaj
Aqueous Humor Outflow Structure and Function Imaging At the Bench and Bedside: A Review. [PDF]
Anterior segment glaucoma clinical care and research has recently gained new focus because of novel imaging modalities and the advent of angle-based surgical treatments. Traditional investigation drawn to the trabecular meshwork now emphasizes the entire
Huang, Alex S +2 more
core +1 more source
Analysis of chromosome positions in the interphase nucleus of Chinese hamster cells by laser-UV-microirradiation experiments [PDF]
Unsynchronized cells of an essentially diploid strain of female Chinese hamster cells derived from lung tissue (CHL) were laser-UV-microirradiated (=257 nm) in the nucleus either at its central part or at its periphery.
B Dutrillaux +38 more
core +1 more source
ObjectiveTo investigate the cost-effectiveness of implementing iStent inject trabecular bypass stent (TBS) in conjunction with cataract surgery (Cat Sx) in patients with mild-to-moderate glaucoma from a societal perspective in France.
Kaspar Nieland +7 more
doaj +2 more sources
Kahook Dual Blade Goniotomy vs iStent inject: Long-Term Results in Patients with Open-Angle Glaucoma
Thorsteinn S Arnljots,1 Mario A Economou2,3 1Anterior Segment Department, St. Erik Eye Hospital, Stockholm, Sweden; 2Division of Ophthalmology and Vision, Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden; 3Department of ...
Arnljots TS, Economou MA
doaj
iStent: Trabecular Micro-Bypass Stent [PDF]
AbstractWithin the class of procedures termed minimally invasive glaucoma surgery (MIGS), the iStent Trabecular Micro-Bypass Stent (Glaukos Corporation, San Clemente, CA, USA) is an intraocular implant that resides within Schlemm’s canal and allows for direct bypass of the trabecular meshwork by aqueous fluid.
Christine L. Larsen, Thomas W. Samuelson
openaire +1 more source
Entanglement as a quantum order parameter [PDF]
We show that the quantum order parameters (QOP) associated with the transitions between a normal conductor and a superconductor in the BCS and eta-pairing models and between a Mott-insulator and a superfluid in the Bose-Hubbard model are directly related
Anfossi A Boschi C D E Montorsi A Ortolani F +15 more