Results 21 to 30 of about 2,084 (194)

Changes in Flow Density Measured Using Optical Coherence Tomography Angiography after iStent Insertion in Combination with Phacoemulsification in Patients with Open-Angle Glaucoma [PDF]

open access: yesJournal of Ophthalmology, 2018
Purpose. To evaluate changes in flow density after the implantation of a trabecular microbypass stent (iStent) in combination with cataract surgery. Methods.
Maged Alnawaiseh   +4 more
doaj   +2 more sources

Efficacy and Safety of Kahook Dual Blade Goniotomy and Trabecular Micro-Bypass Stent in Combination with Cataract Extraction [PDF]

open access: yesBiomimetics
In recent years, rapid advancements in glaucoma research have led to the development of more effective treatments of this chronic and irreversible condition. Of these, Kahook Blade Dual (KDB) goniotomy and second-generation trabecular micro-bypass stent (
Kevin Y. Wu   +3 more
doaj   +2 more sources

Micro-invasive glaucoma surgery (MIGS): a review of surgical procedures using stents [Corrigendum]

open access: yesClinical Ophthalmology, 2018
Pillunat LE, Erb C, Jünemann AGM, et al. Clinical Ophthalmology. 2017;11:1583–1600.Throughout the paper iStent inject® was incorrectly listed as iStent inject or iStent® inject.
Pillunat LE   +3 more
doaj   +1 more source

iStent Trabecular Micro-Bypass Stent Implantation With Cataract Surgery in a Japanese Glaucoma Population

open access: yesClinical Ophthalmology, 2020
Koji Nitta,1 Yutaro Yamada,1 Satomi Morokado,1 Kazuhisa Sugiyama2 1Department of Ophthalmology, Fukui-Ken Saiseikai Hospital, Fukui, Fukui Prefecture, Japan; 2Department of Ophthalmology, Kanazawa University, Kanazawa, Ishikawa Prefecture ...
Koji Nitta, Kazuhisa Sugiyama
exaly   +2 more sources

Comparison of Surgical Outcomes Between Excisional Goniotomy Using the Kahook Dual Blade and iStent Trabecular Micro-Bypass Stent in Combination With Phacoemulsification

open access: yesClinical Ophthalmology, 2019
Dayeong Lee,1 Joshua King,1 Samuel Thomsen,1,2 Matthew Hirabayashi,1 Jella An1,2 1School of Medicine, University of Missouri School of Medicine, Columbia, MO, USA; 2Department of Ophthalmology, Mason Eye Institute, University of Missouri School of ...
Jella An   +2 more
exaly   +2 more sources

Comparison of minimally invasive glaucoma surgery with trabecular micro-bypass stent and microhook ab interno trabeculotomy performed in conjunction with cataract surgery [PDF]

open access: yesInternational Journal of Ophthalmology, 2022
AIM: To evaluate the effectuality and safety of cataract surgery combined with either ab interno trabeculotomy by the microhook (μLOT) or a single iStent® trabecular bypass implantation (iStent) in eyes with cataract and mild-to-moderate glaucoma ...
Naoto Tokuda   +6 more
doaj   +1 more source

Short-term Outcomes and Prognostic Factors of Cataract-combined Surgery with iStent versus iStent Inject [PDF]

open access: yesJournal of the Korean Ophthalmological Society, 2021
Purpose: To analyze the therapeutic effects, prognostic factors, and complications that occurred after iStent<sup>®</sup> or iStent inject<sup>®</sup> implantation in South Korean glaucoma patients. Methods: We retrospectively analyzed 42 eyes of South Korean glaucoma patients, who were followed-up for more than 6 months after ...
Yeseul Gong   +3 more
openaire   +1 more source

Prospective unmasked randomized evaluation of the iStent inject® versus two ocular hypotensive agents in patients with primary open-angle glaucoma

open access: yesClinical Ophthalmology, 2014
Antonio M Fea,1 Jose I Belda,2 Marek Rękas,3 Anselm Jünemann,4 Lydia Chang,5 Luis Pablo,6 Lilit Voskanyan,7 L Jay Katz81Università degli Studi di Torino, Clinica Oculistica, Torino, Italy; 2Hospital Torrevieja Salud, UTE, Servicio de ...
Fea AM   +7 more
doaj   +1 more source

5-year outcomes of single iStent (G1) trabecular microbypass implantation with phacoemulsification in moderately advanced primary open angle glaucoma. [PDF]

open access: yes, 2021
Purpose: To evaluate the safety and efficacy of combined phacoemulsification and single iStent (G1) (iStent, Glaukos Corp. San Clemente, USA), implantation in moderately advanced primary open angle glaucoma (POAG) with 5-years follow-up.
Ansari, E., Ejaz Ansari
core   +1 more source

Performances of glaucoma operations with Kahook Dual Blade or iStent combined with phacoemulsification in Japanese open angle glaucoma patients [PDF]

open access: yesInternational Journal of Ophthalmology, 2020
AIM: To compare surgical outcomes of phacoemulsification combined with glaucoma surgical techniques performed with either Kahook Dual Blade (KDB) or iStent for Japanese patients with either primary open angle glaucoma or exfoliation glaucoma.
Kentaro Iwasaki   +4 more
doaj   +1 more source

Home - About - Disclaimer - Privacy