iStent versus iStent inject implantation combined with phacoemulsification in open angle glaucoma
Purpose: To compare the outcomes of iStent vs. iStent inject implantation combined with phacoemulsification. Methods: This single center retrospective comparative case series included subjects with open angle glaucoma who underwent iStent or iStent ...
Wesam Shamseldin Shalaby +11 more
doaj +3 more sources
Postoperative Endophthalmitis after Combined Cataract Extraction and iStent Inject Implantation
Purpose. To report a case of postoperative endophthalmitis after combined cataract extraction and iStent inject implantation. Observation. A 70-year-old male with a nuclear sclerotic cataract and primary open-angle glaucoma underwent an uneventful ...
Johnson Huang +3 more
doaj +2 more sources
iStent® Trabecular Microbypass Stent: An Update [PDF]
Due to the high rates of complications and failure experienced with current glaucoma procedures, there is a continuous search for a safer and more effective glaucoma surgery.
Arthur Fernandes Resende +3 more
doaj +4 more sources
Uveitis-Glaucoma-Hyphema Syndrome Following iStent Implantation [PDF]
Minimally invasive glaucoma surgery (MIGS) is a subset of glaucoma surgery that is known for its low rate of complications both intraoperatively and postoperatively compared to traditional filtering surgery.
Adam Siedlecki +2 more
doaj +3 more sources
PurposeThe study aimed to compare the 12-month post-operative outcomes of iStent and iStent inject W (inject W), and the factors associated with their success in open-angle glaucoma.MethodsThis single-center, retrospective comparative case series ...
Shuu Morita +4 more
doaj +4 more sources
Comparison of the Intraocular Pressure-Lowering Effect of Minimally Invasive Glaucoma Surgery (MIGS) iStent Inject W and Hydrus—The 12-Month Real-Life Data [PDF]
Background/Objectives: To compare the efficacy and safety of Hydrus® Microstent and iStent inject® W implants, in combination with phacoemulsification, for lowering intraocular pressure (IOP) in patients with glaucoma in a real-world clinical setting ...
Cedric Weich +5 more
doaj +2 more sources
A 2-year longitudinal evaluation of the iStent inject® system for open-angle glaucoma in East Asian eyes [PDF]
BACKGROUND: The aim of the study was to assess the midterm efficacy and safety of the iStent glaucoma device in patients with open-angle glaucoma (OAG). MATERIALS AND METHODS: We conducted a retrospective case series of all patients implanted with iStent
Ru Jian Jonathan Teoh +3 more
doaj +2 more sources
Comparison of minimally invasive glaucoma surgery with trabecular micro-bypass stent and microhook ab interno trabeculotomy performed in conjunction with cataract surgery [PDF]
AIM: To evaluate the effectuality and safety of cataract surgery combined with either ab interno trabeculotomy by the microhook (μLOT) or a single iStent® trabecular bypass implantation (iStent) in eyes with cataract and mild-to-moderate glaucoma ...
Naoto Tokuda +6 more
doaj +1 more source
Association Between Prior Selective Laser Trabeculoplasty and Phaco-iStent Inject Efficacy. [PDF]
ABSTRACT Background To evaluate the association between prior selective laser trabeculoplasty (SLT) on intraocular pressure (IOP) lowering efficacy of phacoemulsification combined with iStent inject (phaco‐iStent). Methods Retrospective study of 1550 eyes of 1023 patients with and without prior SLT that underwent phaco‐iStent.
Tan JCK +8 more
europepmc +2 more sources
Minimally Invasive Glaucoma Surgery: Is It Here to Stay? [PDF]
ABSTRACT The advent of minimally invasive glaucoma surgery (MIGS) has expanded the treatment options available for glaucoma by providing options for reducing intraocular pressure without the serious complication profile associated with incisional glaucoma surgery.
Jain N, Fan Gaskin JC.
europepmc +2 more sources

