Results 21 to 30 of about 34,974 (164)

Retrospective analysis of indications and outcomes of trabecular micro-bypass stent implantation in Indian eyes [PDF]

open access: yesIndian Journal of Ophthalmology
Purpose: To analyze the patient characteristics, initial outcomes, and complications associated with iStent implantation in Indian eyes. Methods: This retrospective case series comprised subjects who underwent iStent, iStent inject, or iStent inject W ...
Amit Pandey   +5 more
doaj   +2 more sources

Micro-invasive glaucoma surgery (MIGS): a review of surgical procedures using stents [Corrigendum]

open access: yesClinical Ophthalmology, 2018
Pillunat LE, Erb C, Jünemann AGM, et al. Clinical Ophthalmology. 2017;11:1583–1600.Throughout the paper iStent inject® was incorrectly listed as iStent inject or iStent® inject.
Pillunat LE   +3 more
doaj   +1 more source

Evaluation of iStent® Inject W in mild to moderate primary open-angle glaucoma – Indian data on pseudophakic eyes [PDF]

open access: yesIndian Journal of Ophthalmology
Purpose: This study aimed to evaluate the safety and efficacy of standalone bilateral iStent® Inject W implantation in pseudophakic patients with mild to moderate primary open-angle glaucoma (POAG) over 18 months. Design: Prospective, longitudinal study.
Chandrima Paul   +2 more
doaj   +2 more sources

Tips and technique for stenting the angle with iStent inject W

open access: yesIndian Journal of Ophthalmology. Case Reports
Background: Minimally invasive glaucoma surgeries are a breakthrough and have added significantly to the glaucoma surgical armamentarium in the recent past.
Sushma Tejwani, Ankit A Shah
doaj   +2 more sources

Prospective unmasked randomized evaluation of the iStent inject® versus two ocular hypotensive agents in patients with primary open-angle glaucoma

open access: yesClinical Ophthalmology, 2014
Antonio M Fea,1 Jose I Belda,2 Marek Rękas,3 Anselm Jünemann,4 Lydia Chang,5 Luis Pablo,6 Lilit Voskanyan,7 L Jay Katz81Università degli Studi di Torino, Clinica Oculistica, Torino, Italy; 2Hospital Torrevieja Salud, UTE, Servicio de ...
Fea AM   +7 more
doaj   +1 more source

Minimally invasive glaucoma surgery: comparison of Hydrus microstent with iStent inject in primary open-angle glaucoma [PDF]

open access: yesBMJ Open Ophthalmology
Background To evaluate and compare the efficacy of a single Hydrus and double iStent inject both combined with cataract surgery for the treatment of primary open-angle glaucoma (POAG).Methods The study was designed as a prospective comparative case ...
Krishna Komzak   +2 more
doaj   +2 more sources

Glaukos iStent inject® Trabecular Micro-Bypass Implantation Associated with Cataract Surgery in Patients with Coexisting Cataract and Open-Angle Glaucoma or Ocular Hypertension: A Long-Term Study [PDF]

open access: yesJournal of Ophthalmology, 2016
Purpose. To evaluate the long-term efficacy and safety of the iStent inject device (Glaukos Corporation, Laguna Hills, CA) combined with phacoemulsification in patients with coexistent cataract and open-angle glaucoma or ocular hypertension (OHT ...
Pedro Arriola-Villalobos   +5 more
doaj   +2 more sources

A prospective analysis of iStent inject microstent positioning

open access: yes, 2019
Precis: A larger proportion of iStent inject microstents than suggested by gonioscopic examination could be entirely burrowed within the trabeculum (45.7%). The length of device protrusion within the anterior chamber is linked to postoperative intraocular pressure (IOP).
Gillmann, Kevin   +3 more
openaire   +3 more sources

Refractive Outcomes After Trabecular Micro-Bypass Stents (iStent Inject) with Cataract Extraction in Open-Angle Glaucoma [PDF]

open access: yesClinical Ophthalmology, 2020
Alexandros S Ioannidis, 1, 2 Marc Töteberg-Harms, 3 Timothy Hamann, 3 Christopher Hodge 1, 4, 5 1Vision Eye Institute Blackburn South, Melbourne, VIC, Australia; 2Royal Melbourne Hospital, Melbourne, VIC, Australia; 3Department of Ophthalmology ...
Ioannidis AS   +3 more
doaj   +2 more sources

Association Between Prior Selective Laser Trabeculoplasty and Phaco-iStent Inject Efficacy. [PDF]

open access: yesClin Exp Ophthalmol
ABSTRACT Background To evaluate the association between prior selective laser trabeculoplasty (SLT) on intraocular pressure (IOP) lowering efficacy of phacoemulsification combined with iStent inject (phaco‐iStent). Methods Retrospective study of 1550 eyes of 1023 patients with and without prior SLT that underwent phaco‐iStent.
Tan JCK   +8 more
europepmc   +2 more sources

Home - About - Disclaimer - Privacy