Comparison of Surgical Outcomes Between iStent Inject W Implantation and Microhook Ab Interno Trabeculotomy in Combination With Phacoemulsification in Primary Open-Angle Glaucoma Patients [PDF]
PurposeTo examine primary open-angle glaucoma patients after undergoing combined cataract surgery with microhook ab interno trabeculotomy (μLOT-Phaco) or iStent inject W implantation (iStent-Phaco), and then evaluate the surgical outcomes after a minimum
Hideaki Okumichi +2 more
exaly +8 more sources
Comparison of the Intraocular Pressure-Lowering Effect of Minimally Invasive Glaucoma Surgery (MIGS) iStent Inject W and Hydrus—The 12-Month Real-Life Data [PDF]
Background/Objectives: To compare the efficacy and safety of Hydrus® Microstent and iStent inject® W implants, in combination with phacoemulsification, for lowering intraocular pressure (IOP) in patients with glaucoma in a real-world clinical setting ...
Nicole Eter +2 more
exaly +7 more sources
A case of two connected stents deployed during iStent inject W surgery [PDF]
Background We report a case with two connected stents ejected simultaneously during an iStent inject W surgery, a modified second-generation iStent Trabecular Micro-Bypass System.
Ayaka Shimada +4 more
doaj +5 more sources
Posture-Induced Intraocular Pressure Changes after iStent Inject W Combined with Phacoemulsification in Open Angle Glaucoma Patients [PDF]
Background and Objectives: The purpose of this study was to evaluate the posture-induced intraocular pressure (IOP) changes after iStent inject W combined with phacoemulsification procedure in Japanese patients with open-angle glaucoma.
Kentaro Iwasaki +3 more
doaj +5 more sources
Comparative evaluation of iStent versus iStent inject W combined with phacoemulsification in open angle glaucoma. [PDF]
PurposeThe study aimed to compare the 12-month post-operative outcomes of iStent and iStent inject W (inject W), and the factors associated with their success in open-angle glaucoma.MethodsThis single-center, retrospective comparative case series ...
Shuu Morita +4 more
doaj +6 more sources
Manipulable preoperative factors affecting surgical outcomes of iStent inject W, particularly the type of antiglaucoma medications. [PDF]
To analyze the surgical outcomes of iStent inject W (ISIW) implantation and investigate the influence of preoperative factors. In total, 114 eyes of 114 patients (mean age, 73.22 ± 7.84 y) were enrolled in this retrospective study. The patients underwent
Sayaka Kimura-Uchida +5 more
doaj +4 more sources
Introduction This study evaluated efficacy and safety of implanting two second-generation trabecular micro-bypass stents (iStent inject/iStent inject W) with phacoemulsification, either with or without iAccess Precision Blade goniotomy, in patients with ...
Mark J Gallardo
exaly +3 more sources
Evaluation of iStent® Inject W in mild to moderate primary open-angle glaucoma – Indian data on pseudophakic eyes [PDF]
Purpose: This study aimed to evaluate the safety and efficacy of standalone bilateral iStent® Inject W implantation in pseudophakic patients with mild to moderate primary open-angle glaucoma (POAG) over 18 months. Design: Prospective, longitudinal study.
Chandrima Paul +2 more
doaj +3 more sources
Retrospective analysis of indications and outcomes of trabecular micro-bypass stent implantation in Indian eyes [PDF]
Purpose: To analyze the patient characteristics, initial outcomes, and complications associated with iStent implantation in Indian eyes. Methods: This retrospective case series comprised subjects who underwent iStent, iStent inject, or iStent inject W ...
Amit Pandey +5 more
doaj +2 more sources
From first generation to the next: evolution and research trends in iStent technology [PDF]
The iStent series constitutes a range of trabecular bypass minimally invasive glaucoma surgery (MIGS) devices, which offers intraocular pressure (IOP) reduction with favourable safety profiles, in patients with open-angle glaucoma (OAG). Having undergone
Bryan Chin Hou Ang +5 more
doaj +2 more sources