[Gender-sensitive health indicators for health reporting at the Robert Koch Institute (GBE-GI)-a pilot project as part of the Joint Action PreventNCD project]. [PDF]
Gencer H, Saß AC, Prütz F.
europepmc +1 more source
An Edible Chitosan‐Based Acoustic Sensor for Sound‐Responsive Actuation in Edible Robots
This study introduces an edible acoustic sensor for robotic food and edible robotics. Built from a chitosan piezoelectric film between gold electrodes, the sensor enables acoustic communication through ON/OFF keying. Integrated into an edible robot with pneumatically actuated arms and neck, it responds to high‐frequency tones.
Valerio Francesco Annese +8 more
wiley +1 more source
Space-time mapping relationships in sensorimotor communication during asymmetric joint action. [PDF]
Zhang K +5 more
europepmc +1 more source
Classifying interpersonal synchrony in VR joint actions: human-human versus human-bot interactions
Yoshiko Arima, Yuki Harada, Mahiro Okada
openalex +1 more source
Coordinated Architectural and Chemical Reinforcement in the Crushing Mandible of a Soldier Termite
The crushing mandible of a soldier termite withstands substantial biting loads despite lacking mineral. Its cuticle is partitioned: convex teeth pair hardness and zinc enrichment with aligned chitin fibers for contact durability, while stiffer concave regions between teeth carry bending loads.
Andrew Tran Nguyen +16 more
wiley +1 more source
Preventing and countering the interference of tobacco industry: Recommendations from the Joint Action on Tobacco Control 2. [PDF]
Solimini R +13 more
europepmc +1 more source
The physical realization of artificial neurons is a critical challenge for energy‐efficient neuromorphic computing. This review presents a comprehensive analysis of the evolution of artificial neuron implementations from conventional CMOS to emerging post‐CMOS technologies.
Kannan Udaya Mohanan +4 more
wiley +1 more source
Unified Action in the Underground: The Joint Fight in the Subterranean Urban Domain
Michael Stanski
openalex +1 more source
Dirac‐Source Linear X‐Ray Detection Diode
Monolayer graphene imparts near linear current‐voltage behavior to a perovskite X‐ray detection diode, contrasting with conventional diode‐like responses. Exploiting graphene's Dirac dispersion and a Schottky‐like back‐to‐back junction, the device achieves six‐orders‐of‐magnitude dark current suppression while retaining linearity over 200 V, enabling ...
Babar Shabbir +8 more
wiley +1 more source

