Results 121 to 130 of about 1,992,035 (378)
Prospective five-year subsidence analysis of a cementless fully hydroxyapatite-coated femoral hip arthroplasty component [PDF]
Early subsidence >1.5 mm is considered to be a predictive factor for later aseptic loosening of the femoral component following total hip arthroplasty (THA).
Clauss, Martin+2 more
core +1 more source
This article describes a multimodal fusion data acquisition and processing system about electromyography for dynamic movement recognition and bioelectrical impedance for key posture recognition. In addition, a new dynamic–static fusion algorithm strategy is designed.
Chenhao Cao+5 more
wiley +1 more source
Researchers have proposed various linkage mechanisms to connect knee and ankle joints for above-knee prostheses, but most of them only offer natural walking. However, studies have shown that people assume a squatting posture during daily activities. This
Amer Imran+2 more
doaj
We demonstrate the direct‐laser patterning of a gold thin film on polymethyl methacrylate to fabricate a temperature sensor for dentures. The temperature sensor‐embedded smart dentures are evaluated in an oral environment, enabling in‐situ monitoring for elderly healthcare.
Han Ku Nam+7 more
wiley +1 more source
A Method to Analyze Dynamics Properties of Transfemoral Prosthesis
.The methodto compute gait cycle forces and moments acting on the hip and knee joints of a lower limb with a trans-femoral prosthesis were investigated. A 3D model of the lower limb with prosthesis was created using CAD software and based on MRI data and
Van Tuan Le+5 more
doaj +1 more source
Temporomandibular Joint Prosthesis in a Patient with Congenital Infiltrating Lipomatosis of the Face with Bony Ankylosis of the Temporomandibular Joint: A Case Report. [PDF]
Bulthuis LCM+5 more
europepmc +1 more source
Principle design of an energy efficient transfemoral prosthesis [PDF]
In the pursuit of realizing an energy efficient transfemoral prosthetic, in this paper we present a preliminary study on a principle design. In particular, the design is based on the idea that the efficiency of the system can be realized by energetically
Carloni, R.+4 more
core +1 more source
Flexibility within the middle ears of vertebrates [PDF]
Introduction and aims: Tympanic middle ears have evolved multiple times independently among vertebrates, and share common features. We review flexibility within tympanic middle ears and consider its physiological and clinical implications.
Baird+36 more
core +1 more source
A Shared Control Method of Multiobjective Motion Fusion for Surgical Robot
This paper proposes an innovative shared control method that can handle multiple objectives task by integrating various types of controllers. It not only takes into account the priorities among the objectives but also allows for the flexible addition or removal of objective controllers.
Xilin Xiao+7 more
wiley +1 more source
State-of-the-art transtibial prostheses provide only ankle joint actuation and thus do not provide the biarticular function of the amputated gastrocnemius muscle.
Michael F. Eilenberg+2 more
doaj +1 more source