Results 1 to 10 of about 10,303 (219)
One purpose of the broader study was to determine whether keratometric measurements obtained with an autokeratometer (Nidek ARK-700) would be comparable with those measured using the Oculus Pentacam(model 70700).
S. Mathebula, A. Rubin
doaj +1 more source
The relationship between central corneal thickness and corneal curvature in adult Nigerians
Purpose: The aim of this study was to provide average values for central corneal thickness (CCT) and corneal curvature (CC) and also to determine a regression model for the relationship between CCT and CC in adult Nigerians without glaucoma. Methods: A
E. Iyamu, N. M. Eze
doaj +1 more source
Effects of rigid high gas-permeable contact lens wear on progression in patient with keratoconus
Wearing Rigid High Gas-Permeable Contact Lens (RGPCL) is a primary method of vision rehabilitation in keratoconus eyes. The aim of the study is to investigate the effects of using RGPCL on the topographical variations at the keratoconus progress.
Tolga Yilmaz +3 more
doaj +1 more source
Keratometry in Pediatric Eyes With Cataract [PDF]
To report the keratometry data of pediatric cataractous eyes (randomly selected single eye of bilateral cases; cataractous eye of unilateral cases) and to compare the keratometry data of the unilateral cataractous eye with the corresponding noncataractous fellow eye.Retrospective review of preoperative data of patients who had undergone cataract ...
Rupal H, Trivedi, M Edward, Wilson
openaire +2 more sources
Keratometry device for surgical support [PDF]
High astigmatisms are usually induced during corneal suturing subsequent to tissue transplantation or any other surgery which involves corneal suturing. One of the reasons is that the procedure is intimately dependent on the surgeon's skill for suturing identical stitches.
Saia Paula +3 more
openaire +3 more sources
Effects of Upper Eyelid Blepharoplasty on Contrast Sensitivity in Dermatochalasis Patients
Objectives:To evaluate the impact of upper eyelid blepharoplasty on contrast sensitivity in dermatochalasis patients.Materials and Methods:Best corrected visual acuity, ophthalmologic examination, eyelid examination, lash ptosis, contrast sensitivity ...
Hilal Nalcı +2 more
doaj +1 more source
The reproducibility of biometry and keratometry measurements [PDF]
Axial length and corneal curvature are entered into formulae to calculate intraocular lens power for cataract surgery and the absolute measurement of fundus structures such as neuroretinal rim area in glaucoma. The reproducibility (coefficient of variation, CV) of biometry and keratometry was investigated by taking five measurements of thirty phakic ...
J M, Butcher, C, O'Brien
openaire +2 more sources
Corneal power modelling with OCT data – Thin and thick lens paraxial models versus raytracing
Abstract Background Evaluating keratometric power with Zeiss index (PKZ), paraxial thick cornea power (Gullstrand [PG]) and power referenced to the front (PFV) and back vertex plane (PBV) and raytracing power (PR), and modelling the deviation from PKZ with a multivariable linear prediction model.
Achim Langenbucher +4 more
wiley +1 more source
Agreement of Total Keratometry and Posterior Keratometry Among IOLMaster 700, CASIA2, and Pentacam
The purpose of this study was to compare total keratometry (TK) and posterior keratometry (PK) obtained by two swept-source optical biometers (IOLMaster 700 and CASIA2) and one Scheimpflug-based topography (Pentacam AXL).The TK and PK in cataract surgery candidates obtained by IOLMaster 700, CASIA2, and Pentacam AXL were compared.
Jin, Aixia +7 more
openaire +2 more sources
Abstract Purpose To evaluate the surgery‐induced changes of astigmatism after Descemet membrane endothelial keratoplasty (DMEK) in eyes with failed previous penetrating keratoplasty (PK). Design Retrospective, interventional cohort study based on prospective DMEK database.
Florian Thomas Steinberg +6 more
wiley +1 more source

