Results 91 to 100 of about 2,915 (206)
Radial keratotomy is effective for correcting low-grade myopia. The predictability is best for myopia that is less than 4 diopters. If the procedure is well performed, the rate of complications remains low. There is not always good correlation between refraction and keratometric changes because of correction errors, which are the main complication ...
A, Prijot, C, Leroy, A, Moutschen
+6 more sources
Extended depth of focus lens implantation after radial keratotomy [Letter]
Arjun SrirampurDepartment of Cornea, Cataract and Refractive Surgery, Anand Eye Institute, Hyderabad 500007, IndiaCorrespondence: Arjun SrirampurAnand Eye Institute, Habsiguda, Hyderabad 500007, IndiaTel +91 998 922 9832Fax +91 402 715 1999Email ...
Srirampur A
doaj
To present a case with progressive keratoconus after treated with radial keratotomy (RK) and was undergone corneal collagen cross-linking (CXL) for preventing the progress of keratectasia. A progressive keratoconus case who was previously treated with RK
Mehmet Ozgur Cubuk, Kamil Bilgihan
doaj +1 more source
Effects of scleral-lens oxygen transmissibility on corneal thickness: A pilot study. [PDF]
PurposeTo investigate the effect of various oxygen transmissibilities (Dk/t) of scleral lenses and corneal thickness recovery time from overnight eye closure with patching on corneal edema during 5 h lens wear.MethodsScleral lenses (hofocon A, 15.6 mm ...
Kim, Young Hyun +5 more
core
Three year results of the Prospective Evaluation of Radial Keratotomy (PERK) study
The Prospective Evaluation of Radial Keratotomy (PERK) study is a nine-center clinical trial of a standardized technique of radial keratotomy in 435 patients who had simple myopia with a preoperative refractive error between -2.00 and -8.00 diopters (D).
Waring III George +9 more
doaj
Purpose. To describe a case of 3 refractive procedures performed in one eye over 2 decades. Methods. Case report. Results. A 41-year-old patient presented for refractive surgery evaluation.
Priyanka Chhadva +3 more
doaj +1 more source
Real-time analysis keratometer [PDF]
A computer assisted keratometer in which a fiducial line pattern reticle illuminated by CW or pulsed laser light is projected on a corneal surface through lenses, a prismoidal beamsplitter quarterwave plate, and objective optics.
Adachi, Iwao P. +2 more
core +1 more source
Granular Corneal Dystrophy Manifesting after Radial Keratotomy
<!--[if gte mso 9]><xml> Normal 0 false false false MicrosoftInternetExplorer4 </xml><![endif]--><!--[if gte mso 9]><xml> </xml><![endif]--> <!--[if gte mso 10]> <style> /* Style ...
Sepehr Feizi +3 more
doaj

