Results 71 to 80 of about 872,819 (289)
Regional anesthesia for knee and hip arthroplasty may have favorable outcome effects compared with general anesthesia by effectively blocking afferent input, providing initial postoperative analgesia, reducing endocrine metabolic responses, and providing
Henrik Kehlet, Eske Kvanner Aasvang
doaj +1 more source
NeuroVisio SyncPatch integrates skin‐conformal electromyography (EMG) electrodes with camera‐tracked markers to jointly assess muscle activity and three‐dimensional knee kinematics during rehabilitation. Parallel feedback pathways provide real‐time kinematic guidance during movement and post‐trial neuromuscular feedback.
Bohyung Choi +11 more
wiley +1 more source
Comparison of two methods for probabilistic finite element analysis of total knee replacement
Probabilistic Finite Element (FE) models have recently been developed to assess the impact of experimental variability present in knee wear simulator on predicted Total Knee Replacement (TKR) mechanics by determining the performance envelope of joint ...
Arsene, C.T.C. +3 more
core +1 more source
Fiber‐Format Flexible Linear Electrostatic Motors
A flexible coaxial fibre‐format electrostatic motor enables backdrivable and reversible linear actuation with high force density and functionality under bending, offering a scalable actuation platform for soft and wearable robotics. ABSTRACT Linear motion is fundamental to robotics, yet existing solutions are either rigid electromagnetic motors or ...
Sylvain Schaller, Herbert Shea
wiley +1 more source
Background Total knee replacement is a common operative procedure to improve pain, function, and quality of life in patients with end stage knee osteoarthritis.
Ahmad H. Alghadir +3 more
doaj +1 more source
Outcomes for revision total knee replacement after unicompartmental knee replacement
Abstract Objective: The aim of this retrospective, observational study was to describe the outcomes of total knee replacement (TKR) after failed Oxford phase 3 medial unicompartmental knee replacement (UKR). Methods: The study included 24 revision TKRs (20 females, 4 males; mean age: 61 years) performed following failed aseptic UKR.
Burak, Akan +5 more
openaire +2 more sources
An All‐Fabric Wearable System for Human‐Machine Interaction
An all‐fabric sensing system enables wearable human–machine interaction through a breathable, stretchable, and scalable design. The all‐fabric capacitive sensor achieves a gauge factor of 2.03 over 72% strain and supports body‐motion tracking, 90.5% hand gesture recognition, and real‐time prosthetic hand control, demonstrating a promising pathway ...
Rayane Tchantchane +3 more
wiley +1 more source
Aims: Sagittal plane imbalance (SPI), or asymmetry between extension and flexion gaps, is an important issue in total knee arthroplasty (TKA). The purpose of this study was to compare SPI between kinematic alignment (KA), mechanical alignment (MA), and ...
Victor A. van de Graaf +4 more
doaj +1 more source
Pak Biawak, a necrobot, embodies an unusual fusion of biology and robotics. Designed to repurpose natural structures after death, it challenges conventional boundaries between nature and engineering. Its movements are precise yet unsettling, raising questions about sustainability, ethics, and the untapped potential of biointegrated machines.
Leo Foulds +2 more
wiley +1 more source
Compliant Pneumatic Feet with Real‐Time Stiffness Adaptation for Humanoid Locomotion
A compliant pneumatic foot with real‐time variable stiffness enables humanoid robots to adapt to changing terrains. Using onboard vision and pressure control, the foot modulates stiffness within each gait cycle, reducing impact forces and improving balance. The design, cast in soft silicone with embedded air chambers and Kevlar wrapping, offers durable,
Irene Frizza +3 more
wiley +1 more source