Results 171 to 180 of about 30,344 (216)
Abstract This study aimed to evaluate the dose‐exposure reduction effect of a crystalline lens with a bismuth eye shield using cone‐beam computed tomography (CBCT) for head image‐guided radiation therapy. The ocular surface dose of the head phantom (THRA‐1) is defined as a crystalline lens exposure dose and is measured using a radiophotoluminescence ...
Tatsuya Yoshida+5 more
wiley +1 more source
Abstract Background Volumetric modulated arc therapy (VMAT) requires an accurate patient‐specific quality assurance (PSQA) program. In clinical practice, this is usually performed using the γ‐index and the two‐dimensional gamma passing rate (2D %GP). A three‐dimensional (3D) index incorporating the patient anatomy could be more useful for the 3D dose ...
Christos Zarros+6 more
wiley +1 more source
Evaluation of daily residual pancreatic tumor motion for deep‐inspiration breath‐hold radiotherapy
Abstract Purpose Breath‐hold techniques are widely used in radiation therapy to minimize respiratory‐induced tumor or organ‐at‐risk motion. However, residual motion persists, necessitating a reliable daily evaluation method. Methods At our institution, fiducial markers serve as surrogates for target localization in pancreatic cancer treatment.
Weihua Mao+4 more
wiley +1 more source
Abstract Purpose This study compares the dosimetric accuracy of deep‐learning‐based MR synthetic CT (sCT) in brain radiotherapy between the Analytical Anisotropic Algorithm (AAA) and AcurosXB (AXB). Additionally, it proposes a novel metric to predict the dosimetric accuracy of sCT for individual post‐surgical brain cases.
Jeffrey C. F. Lui+3 more
wiley +1 more source
A review of artificial intelligence in brachytherapy
Abstract Artificial intelligence (AI) has the potential to revolutionize brachytherapy's clinical workflow. This review comprehensively examines the application of AI, focusing on machine learning and deep learning, in various aspects of brachytherapy.
Jingchu Chen+4 more
wiley +1 more source
Abstract The thermoluminescence dosimeter (TLD) sheet is a measurement device coated with manganese‐doped LiB3O5 in sheet form. The sheet is 0.2‐mm thick and flexible. Hence, it can fit and be installed on irregular surfaces. The current study aimed to evaluate the feasibility of measuring patient surface doses during radiation therapy using TLD sheets.
Yuya Miyasaka+8 more
wiley +1 more source
Abstract Skin flash is typically added to breast and chestwall plans to ensure robust target coverage in the presence of respiratory motion, anatomic changes, and small setup uncertainties. Adding skin flash in volumetric modulated arc therapy (VMAT) plans is an iterative and manual process.
Emily Hubley+6 more
wiley +1 more source
Abstract Purpose Palliative radiotherapy comprises a significant portion of the radiation treatment workload. Volumetric‐modulated arc therapy (VMAT) improves dose conformity and, in conjunction with flattening filter free (FFF) delivery, can decrease treatment times, both of which are desirable in a population with a high probability of retreatment ...
Madeleine L. Van de Kleut+2 more
wiley +1 more source
Abstract Background To assess the dose‐sparing capabilities of a yaw‐limited volumetric modulated arc therapy (YL_VMAT) beam setup for adjacent organs at risk (OAR) in comparison with 3D‐conventional radiation therapy (3D‐CRT), intensity‐modulated radiation therapy (IMRT) and conventional VMAT for radiation therapy in left‐sided breast cancer patients.
Gerhard Pollul+4 more
wiley +1 more source