Hole gratings for laser damage testing

Applied Optics, 1983
The use of hole gratings in small-spot laser damage testing is discussed. If the intensity loss due to the transmission of the grating and due to the production of several spots can be tolerated, a hole grating is shown to increase the ease of establishing a damage threshold by the production of spots with a wide range of intensities whose ratios are ...
T A, Wiggins, T T, Saito, R M, Herman
openaire   +2 more sources

Device for reusing damaged laser mirrors

Review of Scientific Instruments, 1979
A simple mirror holder which permits the use of locally damaged laser morrors by allowing the undamaged areas of the reflector to be aligned along the laser optic axis is described. The mirror holder has an eccentric step for housing the mirror and a concentric aperture through which the undamaged surface of the reflector is utilised.
Prasad, CR   +2 more
openaire   +2 more sources

The Threshold of the Retina to Damage by Laser Energy

Archives of Ophthalmology, 1966
The laser is one of the more important recent developments in the field of the physical sciences. Research on lasers and their application is progressing on an ever widening base with an increasing number of actively participating personnel. The unique laser qualities and the ocular hazards associated with them mean that the determination of safety ...
C J, Campbell   +4 more
openaire   +2 more sources

Laser Damage in Materials

Optical Engineering, 1983
Laser damage of optical components is an important issue facing the optical engineer of today. The lifetime of the components not only affects the design of the laser system, but also can involve long downtime for replacement of components that may require careful alignment.
openaire   +1 more source

Corneal Endothelial Damage with Neodymium:YAG Laser

Ophthalmology, 1984
Acute corneal endothelial changes following Nd:YAG laser application were evaluated in two series of rabbits. The first series underwent anterior capsulotomy, while the second series received laser applications at calculated distances ranging from 0.0 mm to 1.8 mm posterior to the endothelium.
K T, Meyer, T H, Pettit, B R, Straatsma
openaire   +2 more sources

Laser Damage Thresholds for Ocular Tissues

American Industrial Hygiene Association Journal, 1969
Abstract Safe laser exposure levels have enormous commercial and military ramifications and must be set neither too high nor too low. Linear thermal models indicate ranges over which thresholds increase with increasing exposure time and decreasing spot size. Reported thresholds depend on the damage criterion used.
N A, Peppers, A H, Hammond
openaire   +2 more sources

Effect of laser therapy on DNA damage

Lasers in Surgery and Medicine, 2010
AbstractBackground and ObjectiveWhereas the biostimulative effect on tissues using low intensity laser therapy for treating many diseases has been described, the photobiological basis and adverse effects are not well understood. The aim of this study, using experimental models, is to observe the combined effect of physical damage (laser) and a chemical
Adenilson S, Fonseca   +7 more
openaire   +2 more sources

Pulsed laser damage to optical fibers

Applied Optics, 1985
This paper describes some observations of pulsed laser damage to optical fibers with emphasis on a damage mode characterized as a linear fracture along the outer core of a fiber. Damage threshold data are presented which illustrate the effects of the focusing lens, end-surface preparation, and type of fiber.
S W, Allison   +3 more
openaire   +2 more sources

Prediction of Laser Induced Damage by Comparison of Laser Fluence Profile to Damage Spot Radius

Laser-Induced Damage in Optical Materials 1989, 1990
In this method, the laser induced damage threshold for a material is obtained by determining the fluence within the damaging beam at a radial distance equal to the radius of the damage spot. The energy profile of the laser pulse is determined by translating a slit across the beam and reading the energy passing through the slit with position.
R Goedert, T Whittaker, D Templeton
openaire   +2 more sources

Neodymium:YAG laser damage of intraocular lenses

Journal of Cataract and Refractive Surgery, 1988
Intraocular lenses (IOLs) suitable for implantation were analyzed for the presence of refractile particles. These were found in lathe-cut and injection-molded lenses from various manufacturers. A YAG laser was focused 2 mm beyond the IOLs in a special test chamber and fired through them. The IOLs were then analyzed for damage.
S G, Smith, F M, Snowden
openaire   +2 more sources