Results 91 to 100 of about 126,256 (297)
Through direct application of porous transport layer (PTL) on the bipolar plate (BPP) with thermal spraying, the interfacial contact resistance is improved. With the cold gas sprayed BPP–PTL coating system, a proton exchange membrane water electrolysis cell with a cell voltage of Ucell = 1.9 V can be operated up to i = 2.5 A/cm2 in a dynamic mode ...
Kirsten Bobzin +5 more
wiley +1 more source
Long-distance measurements (10 m - 1000 m) with an accuracy of 10-7 is a challenge for many applications. We show that it is achievable with Frequency Shifted Feedback (FSF) laser interferometry technique, provided that the determination of the radio ...
Amann +22 more
core +5 more sources
Low‐Angle Grain Boundaries and Re‐Segregation in Single‐Crystalline Ni‐Base Superalloys
This work demonstrates that Re‐segregation at low‐angle grain boundaries (LAGBs) in Ni‐base superalloys is influenced by misorientation angle. Advanced microscopy and atom probe tomography reveal that higher misorientation angles increases Re‐segregation.
Alireza B. Parsa +9 more
wiley +1 more source
Single-Element Dual-Interferometer for Precision Inertial Sensing: Sub-Picometer Structural Stability and Performance as a Reference for Laser Frequency Stabilization. [PDF]
Huarcaya V +9 more
europepmc +1 more source
EDX elemental map of the pre‐oxidized MgO–steel cermet anode cross section after electrolysis. The development of inert anodes for aluminum electrolysis remains challenging due to the high corrosivity of cryolite‐based melts at 950°C–1000°C. This study investigates the corrosion and process behavior of a carbon‐free MgO–steel cermet anode derived from ...
Alexander Adamczyk +7 more
wiley +1 more source
Investigation of laser dynamics, modulation and control by means of intra-cavity time varying perturbation Semiannual status report [PDF]
Laser dynamics, control, and stabilization of optical frequency ...
Harris, S. E.
core +3 more sources
Micro‐Raman spectroscopy is applied to characterize corrosion products in a recycled‐based MgO–316L steel composite anode after molten salt electrolysis. A depth‐dependent Fe–O/Fe–Al–O layer sequence of magnetite, hercynite, and an Al‐doped magnetite transition zone is identified.
Felix Drechsler +9 more
wiley +1 more source
We present a robust self-heterodyne mixing method of two inter-mode beat frequencies suitable for frequency stabilization of a three longitudinal-mode (3-mode) He-Ne laser at 633 nm.
Jeongmin Lee, Tai Hyun Yoon
doaj +1 more source
Calibrating an interferometric laser frequency stabilization to MHz precision
We report on a calibration procedure that enhances the precision of an interferometer based frequency stabilization by several orders of magnitude.
Barwood +6 more
core +1 more source
Microresonator-stabilized extended-cavity diode laser for supercavity frequency stabilization
We demonstrate a simple, compact, and cost-effective laser noise reduction method for stabilizing an extended cavity diode laser to a 3x105 finesse mirror Fabry-P rot (F-P) cavity corresponding to resonance linewidth of 10 kHz using a crystalline MgF2 whispering gallery mode microresonator (WGMR).
Lim, Jinkang +5 more
openaire +3 more sources

