Results 171 to 180 of about 3,011 (219)
Some of the next articles are maybe not open access.

Laser iridectomy treatment of acute pseudophakic pupillary block glaucoma

American Intra-Ocular Implant Society Journal, 1982
A 71-year-old patient developed acute pupillary block glaucoma two years after uncomplicated extracapsular cataract surgery with primary implantation of a Choyce-style anterior chamber lens. He presented one week after the onset of pain. The attack was relieved with argon laser iridectomy. The presumed mechanism was rotation of the intraocular lens due
N, Kokoris, J I, Macy
openaire   +2 more sources

Corneal Decompensation After Argon Laser Iridectomy-A Delayed Complication

Ophthalmic Surgery, Lasers and Imaging Retina, 1991
ABSTRACT We report six eyes in six patients in which corneal decompensation developed 18 or more months after argon laser iridectomy (ALI). In addition to the level of laser energy used, other risk factors included performing ALI during an attack, diabetes, and a cornea damaged by glaucomatous attack.
S, Jeng, J S, Lee, S C, Huang
openaire   +2 more sources

A Simplified Technique for Laser Iridectomy in Blue Irides

American Journal of Ophthalmology, 1983
Although some investigators have successfully performed argon laser iridectomies in blue irides, penetration is frequently difficult, particularly in light blue and gray irides with filmy stroma and poorly defined or absent crypts. Among the problems are an inability to penetrate the stroma with routine penetrating burns (spot size, 50 μm; power, 500 ...
D, Stetz, H, Smith, R, Ritch
openaire   +2 more sources

Continuous Wave Argon Laser Iridectomy in Angle-Closure Glaucoma

American Journal of Ophthalmology, 1979
Utilizing a continuous wave argon laser in a multiburn fashion, successful iridectomies were achieved in 42 of 45 phakic eyes with either acute or chronic angle-closure glaucoma. Five of the successful procedures required multiple sittings on different days or abandonment of the primary treatment site in favor of an alternate site to attain patency ...
S M, Podos   +4 more
openaire   +3 more sources

Posterior synechiae after laser iridectomy.

Annals of ophthalmology, 1989
Eighty-six eyes of 46 patients were studied retrospectively to determine the incidence of posterior synechiae after laser iridectomy. All eyes were dilated and studied with a slit lamp. The incidence of permanent posterior synechiae in the eyes in this study (37%) is much higher than that previously reported.
C M, Lederer, P K, Price
openaire   +1 more source

Laser Iridectomy in the Management of Chronic Angle-Closure Glaucoma

American Journal of Ophthalmology, 1984
Nineteen eyes of 16 patients (12 men and four women ranging in age from 41 to 75 years) underwent laser peripheral iridectomy for treatment of uncontrolled chronic angle-closure glaucoma (25 to 62 mm Hg). Five of eight eyes (62.5%) with glaucomatous cupping but full visual fields attained postiridectomy intraocular pressures of less than 22 mm Hg with ...
D K, Gieser, J T, Wilensky
openaire   +2 more sources

[Laser Iridectomy (author's transl)].

Klinische Monatsblatter fur Augenheilkunde, 1982
During the period mentioned 150 laser iridectomies were performed using the pulsed argon laser (BRITT Corp). With the help of a specially developed three mirror glass, (Stiegler) it is possible, without exception, to penetrate the iris in one session, regardless of its color or the depth of the anterior chamber.
openaire   +1 more source

Laser Iridectomies

American Journal of Ophthalmology, 1971
H, Beckman   +4 more
openaire   +2 more sources

Laser Iridectomy-1992

Seminars in Ophthalmology, 1992
C D, Belcher, J S, Schuman
openaire   +2 more sources

Delayed hyphema after argon laser iridectomy.

Ophthalmic surgery, 1985
A 77-year-old black woman without neovascularization developed spontaneous hyphema two days after laser iridectomy. Bleeding originated at the site of iridectomy. This complication has not been previously reported.
L, Rubin, J, Arnett, R, Ritch
openaire   +1 more source

Home - About - Disclaimer - Privacy