Results 41 to 50 of about 177,323 (293)
In this study, we found that human cervical‐derived adipocytes maintain intracellular iron level by regulating the expression of iron transport‐related proteins during adrenergic stimulation. Melanotransferrin is predicted to interact with transferrin receptor 1 based on in silico analysis.
Rahaf Alrifai +9 more
wiley +1 more source
Scanned-cantilever atomic force microscope [PDF]
We have developed a 3.6 µm scan range atomic force microscope that scans the cantilever instead of the sample, while the optical-lever detection apparatus remains stationary.
Baldeschwieler, John D. +1 more
core +2 more sources
Cell surface interactome analysis identifies TSPAN4 as a negative regulator of PD‐L1 in melanoma
Using cell surface proximity biotinylation, we identified tetraspanin TSPAN4 within the PD‐L1 interactome of melanoma cells. TSPAN4 negatively regulates PD‐L1 expression and lateral mobility by limiting its interaction with CMTM6 and promoting PD‐L1 degradation.
Guus A. Franken +7 more
wiley +1 more source
Background: Early assessment of cranial deformities in newborns, such as plagiocephaly, brachycephaly, dolichocephaly, turricephaly, and trigonocephaly, requires precise and non-invasive methods.
Omar C. Quispe-Enriquez +1 more
doaj +1 more source
Nanosecond infrared laser (NIRL) low‐volume sampling combined with shotgun lipidomics uncovers distinct lipidome alterations in oropharyngeal squamous cell carcinoma (OPSCC) of the palatine tonsil. Several lipid species consistently differentiate tumor from healthy tissue, highlighting their potential as diagnostic markers.
Leonard Kerkhoff +11 more
wiley +1 more source
Evaluation and comparison of surface macrotexture and friction measurement methods
Two- and three-dimensional macrotexture characteristics of various surfaces were measured using five different testing methods including sand patch method, laser profiler, laser texture scanner, circular texture meter, and x-ray computed tomography (CT ...
Halil Sezen, Nicholas Fisco
doaj +1 more source
Comparison of a three dimensional laser scanner with coordinate measuring machine in arch drawing [PDF]
Background and aim: The aim of present study was to compare the 4th degree polynomials’ drawings generated by the invented laser scanner and ones generated by a CMM. Materials and methods: This diagnostic experimental study was conducted on maxillary and
Mahtab Nouri +2 more
doaj +1 more source
Aplikasi Terrestrial Laser Scanner Untuk Pemodelan Tampak Muka Bangunan (Studi Kasus: Gedung PT. Almega Geosystems, Kelapa Gading-Jakarta) [PDF]
Perkembangan dunia survei dan pemetaan sangatlah pesat. Di era sekarang ini, pemanfaatan teknologi Terrestrial Laser Scanner dapat memberikan solusi untuk pendokumentasian suatu bangunan maupun pengukuran topografi.
Kahar, S. (Sutomo) +2 more
core
Calibration and accuracy assessment of Leica ScanStation C10 terrestrial laser scanner [PDF]
Requirement of high accuracy data in surveying applications has made calibration procedure a standard routine for all surveying instruments. This is due to the assumption that all observed data are impaired with errors.
Abbas, Mohd Azwan +5 more
core +1 more source
Aptamers are used both therapeutically and as targeting agents in cancer treatment. We developed an aptamer‐targeted PLGA–TRAIL nanosystem that exhibited superior therapeutic efficacy in NOD/SCID breast cancer models. This nanosystem represents a novel biotechnological drug candidate for suppressing resistance development in breast cancer.
Gulen Melike Demirbolat +8 more
wiley +1 more source

