Results 1 to 10 of about 5,121 (217)

Seven Level Inverter LCL Filter

open access: yesInternational Journal For Multidisciplinary Research, 2023
The paper presents the controlling of current in single phase grid connected seven level multiinverter with boostup operation. Here we get output as 1.5 times of input using charge pump principle with less harmonic distortions. By using LCL filter we can control the current which removes the LCL resonance and maintain the stability at different ...
Yamuna Pagidela, Sailaja K
openaire   +1 more source

Single-Sensor Control of LCL-Filtered Grid-Connected Inverters [PDF]

open access: yesIEEE Access, 2019
Owing to the filter resonance and background harmonics, the current control for the LCL-filtered grid-connected inverter should be carefully designed to ensure stable operation. Prior-art current control methods normally require extra sensors to achieve the damping of the resonance, or sophisticated active damping should be employed.
Mei Su   +7 more
openaire   +3 more sources

Optimization of LCL Filter Grid-Connected Inverters

open access: yesAcademic Journal of Science and Technology, 2023
 The increasing use of grid-connected inverters in power systems, driven by renewable energy growth and high-voltage, high-power open-loop devices, poses challenges due to PWM modulation generating harmful high-frequency harmonic currents. Optimizing parameter selection becomes crucial.LCL grid-connected inverters, as third-order systems, suffer from ...
openaire   +1 more source

An Electrical Machine with Integrated Drive LCL Filter Components [PDF]

open access: yes8th IET International Conference on Power Electronics, Machines and Drives (PEMD 2016), 2016
In recent years, integrated passive components technology has gained significant popularity in integrated drives research. An integrated drive may be considered to be a full mechanical integration of the machine, power electronic converter and passive components into a single package. This approach is important for applications such as traction motors,
Mohamed, M.A.   +4 more
openaire   +1 more source

Transformer and LCL Filter Design for DPFCs [PDF]

open access: yes, 2014
Flexible AC Transmission Systems (FACTS) can be used for power flow control in AC transmission grids, allowing simultaneous control of the bus voltage and line active and reactive power. However, due to high costs and reliability concerns, the application of this technology has been limited in such applications.
Martins, I. E.   +3 more
openaire   +3 more sources

Analysis and design of LCL filter based synchronverter [PDF]

open access: yes2017 IEEE Energy Conversion Congress and Exposition (ECCE), 2017
Electrical energy generation is evolving from centralized towards distributed energy resources (DER) like wind and solar power plants. In such power systems, new challenges arise for the design of voltage source converter (VSC) control strategies.
Roberto Rosso   +4 more
openaire   +1 more source

Research on LCL filter considering grid impedance

open access: yesIOP Conference Series: Earth and Environmental Science, 2019
Abstract Due to the large amount of access to distributed energy, the grid usually exhibits weak grid characteristics, which puts higher demands on the inverter. The use of LCL filters in photovoltaic grid-connected systems is beneficial to suppress high-frequency switching harmonic currents from entering the grid.
L F Wu, C Z Zhang
openaire   +1 more source

Capacitive Emulation for LCL-Filtered Grid-Connected Converters [PDF]

open access: yesEnergies, 2017
This paper proposes an effective capacitive emulation (CE) technique to reduce the grid current distortion when the converter currents are controlled (converter current feedback (CCF)) in grid-connected converters with an LCL filter. Although the CCF scheme is preferable to the grid current feedback (GCF) scheme in terms of stability and inherent ...
Jose Espi   +2 more
openaire   +2 more sources

Stability of Grid-Connected Inverter with LCL Filter

open access: yesTRANSACTIONS ON ELECTRICAL ENGINEERING, 2020
<p>The paper analyses oscillations in a single-phase grid connected inverter with the LCL output filter. Passive and active damping techniques are designed and compared by simulations. The inverter is controlled by a proportional resonant controller.</p>
Marek Pástor, Jaroslav Dudrik
openaire   +1 more source

Wide frequency range active damping of LCL‐filtered grid‐connected converters [PDF]

open access: yesThe Journal of Engineering, 2019
It can be challenging to guarantee the stability of grids with many converters with LCL filters connected due to the presence of multiple resonances within the system. This paper presents an active damping technique to mitigate multiple resonance effects and harmonics in power converters connected to weak grids.
Abdelhady Ghanem   +5 more
openaire   +2 more sources

Home - About - Disclaimer - Privacy