Impact of atrial fibrillation on the cardiovascular system through a lumped-parameter approach [PDF]
Atrial fibrillation (AF) is the most common arrhythmia affecting millions of people in the Western countries and, due to the widespread impact on the population and its medical relevance, is largely investigated in both clinical and bioengineering ...
Camporeale, Carlo +3 more
core +2 more sources
ABSTRACT The rapid evolution of the Internet of Things (IoT) has significantly advanced the field of electrocardiogram (ECG) monitoring, enabling real‐time, remote, and patient‐centric cardiac care. This paper presents a comprehensive survey of AI assisted IoT‐based ECG monitoring systems, focusing on the integration of emerging technologies such as ...
Amrita Choudhury +2 more
wiley +1 more source
Echocardiography combined with cardiopulmonary exercise testing for the prediction of outcome in idiopathic pulmonary arterial hypertension [PDF]
BACKGROUND: Right ventricular (RV) function is a major determinant of exercise intolerance and outcome in idiopathic pulmonary arterial hypertension (IPAH). The aim of the study was to evaluate the incremental prognostic value of echocardiography of the
Badagliacca, Roberto +11 more
core +1 more source
A modified approach was developed to accurately identify the isovolumetric relaxation time (IVRT) using an apical three‐chamber view. Compared with conventional echocardiography, isovolumic relaxation strain imaging (IVSI) helps to detect the earlier alternations of diastolic function in transverse aortic constriction (TAC) mice.
Jingjing Liang +3 more
wiley +1 more source
Volumetric preload measurement by thermodilution: a comparison with transoesophageal echocardiography [PDF]
Background. End-diastolic volume indices determined by transpulmonary thermodilution and pulmonary artery thermodilution may give a better estimate of left ventricular preload than pulmonary capillary wedge pressure monitoring.
Furrer, L. +6 more
core
What every ICU clinician needs to know about the cardiovascular effects caused by abdominal hypertension [PDF]
The effects of increased intra-abdominal pressure (IAP) on cardiovascular function are well recognized and include a combined negative effect on preload, afterload and contractility.
De Keulenaer, Bart L +2 more
core +1 more source
Wireless blood pressure sensor implantation in sheep: A detailed technique
Twelve adult sheep underwent wireless blood pressure sensor implantation. The procedure lasted an average of 36 min, with mean systolic and diastolic blood pressures of 93 ± 6 and 65 ± 5 mmHg, respectively. This rapid, minimally invasive protocol is a powerful platform for cardiovascular device development.
David Santer +10 more
wiley +1 more source
Effect of prolonged space flight on cardiac function and dimensions [PDF]
Echocardiographic studies were performed preflight 5 days before launch and on recovery day and 1, 2, 4, 11, 31 and 68 days postflight. From these echocardiograms measurements were made.
Epstein, S. E. +4 more
core +1 more source
Soluble ST2 levels and left ventricular structure and function in patients with metabolic syndrome [PDF]
Background: A biomarker that is of great interest in relation to adverse cardiovascular events is soluble ST2 (sST2), a member of the interleukin family.
Beunza, Maite +14 more
core +1 more source
Equine models in translational medicine: A comparative approach to human health
This diagram summarizes and contrasts rodent and equine models, outlining their strengths, limitations, and applications. Horses offer naturally occurring diseases, genetic and physiological similarities to humans, and suitability for longitudinal and clinical‐scale studies.
Shayan Boozarjomehri Amnieh +1 more
wiley +1 more source

