Results 141 to 150 of about 2,022,016 (225)
Biomarkers of ventricular remodelling in African hypertensives. [PDF]
Includes abstract.Includes bibliographical references.There is substantial evidence that the burden of hypertension, hypertension with left ventricular hypertrophy and hypertensive heart failure is very enormous in sub-Saharan Africa.
Dike, Ojji
core +1 more source
Atrial pacing failure after pacemaker implantation does not always indicate lead malfunction. Non‐invasive assessment can identify the underlying cause and may avoid unnecessary lead revision.
Ayano Shibata +4 more
wiley +1 more source
Is Left Bundle Branch Pacing Feasible in Patients With Ventricular Septal Defect?
His bundle typically passes through the central fibrous body of the atrioventricular node and then enters the membranous portion of the interventricular septum, where it branches into the left and right bundle branches. The feasibility and safety of left
Binbin Luo +3 more
doaj +1 more source
(A) Unscrewing of AVEIR AR. (B) After unscrewing, the device appeared to be trapped with the stretched helix. (C) Successful retrieval was achieved by fully covering the device. (D) The retrieved device demonstrated the stretched helix. ABSTRACT An 81‐year‐old woman with a medical history of mechanical mitral valve replacement, Maze procedure, and ...
Toshiya Yoshida +4 more
wiley +1 more source
Pulsed‐field ablation was safely performed in a patient with atrial fibrillation and partial anomalous pulmonary venous return. Electroanatomical mapping defined the sinus node region and confirmed sufficient distance from anomalous right pulmonary vein ablation sites, enabling successful isolation.
Keisho Kurokawa +6 more
wiley +1 more source
Background: Variation in human left bundle branch (LBB) anatomy has a significant effect on the sequence of left ventricular depolarization. However, little is known regarding the electrophysiological characteristics of pacing different LBB fascicles ...
Álvaro Estévez Paniagua +3 more
doaj +1 more source
After unsuccessful implantation at the conventional right atrial appendage site, an atrial leadless pacemaker was implanted at the high right atrial septum. Electrical parameters were maintained during 6‐month follow‐up.
Morio Ono +4 more
wiley +1 more source
Coexistence of Atrioventricular Nodal Reentrant Tachycardia and Idiopathic Left Ventricular Outflow-Tract Tachycardia [PDF]
Double tachycardia is a relatively rare condition. We describe a 21 year old woman with history of frequent palpitations. In one of these episodes, she had wide complex tachycardia with right bundle branch and inferior axis morphology.
Arash Arya +13 more
core
BackgroundThe effect of right ventricular (RV) lead position on the response to cardiac resynchronization therapy (CRT) remains unclear. We evaluated the effects of different RV lead positions on electrophysiology, echocardiography, and clinical outcomes.
Yanfei Wang +9 more
doaj +1 more source
Stepwise evaluation of fractionation and peak frequency maps on substrate mapping identified VT‐related substrate regions in a patient with multiple ventricular tachycardias. This complementary substrate‐based approach may help guide ablation when complete circuit characterization is challenging.
Maiko Kuroda +2 more
wiley +1 more source

