Results 91 to 100 of about 724,370 (321)

Toxic Anterior Segment Syndrome (TASS)

open access: yesTürk Oftalmoloji Dergisi, 2011
Toxic anterior segment syndrome (TASS) is a sterile intraocular inflammation caused by noninfectious substances, resulting in extensive toxic damage to the intraocular tissues.
Özlem Öner   +2 more
doaj   +1 more source

Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics [PDF]

open access: yes, 2017
Wearable contact lenses which can monitor physiological parameters have attracted substantial interests due to the capability of direct detection of biomarkers contained in body fluids. However, previously reported contact lens sensors can only monitor a
BL Due   +47 more
core   +1 more source

Causes and correction of dissatisfaction after implantation of presbyopia-correcting intraocular lenses

open access: yesClinical Ophthalmology, 2016
Purpose The purpose of this study was to assess the causes and possible solutions for patient dissatisfaction after the implantation of presbyopia-correcting intraocular lenses (IOLs).
A. Gibbons   +3 more
semanticscholar   +1 more source

Temporal multiplexing with adaptive optics for simultaneous vision. [PDF]

open access: yes, 1998
We present and test a methodology for generating simultaneous vision with a deformable mirror that changed shape at 50 Hz between two vergences: 0 D (far vision) and -2.5 D (near vision).
Papadatou, E   +3 more
core   +2 more sources

Light‐Based Molecular Tools to Precisely Monitor and Operate β‐Adrenoceptors

open access: yesMedicinal Research Reviews, EarlyView.
ABSTRACT β‐Adrenoceptors are important G protein–coupled receptors involved in cardiovascular, metabolic, and neurological regulation. To study their function with high precision, light‐based molecular tools have been developed offering precise spatiotemporal control.
Ignazzitto Maria Tindara   +3 more
wiley   +1 more source

Accessible digital ophthalmoscopy based on liquid-lens technology [PDF]

open access: yes, 2015
Ophthalmoscopes have yet to capitalise on novel low-cost miniature optomechatronics, which could disrupt ophthalmic monitoring in rural areas. This paper demonstrates a new design integrating modern components for ophthalmoscopy.
Bergeles, C   +8 more
core   +1 more source

Mydriasis as a Secondary Effect in Patients With HLA‐B27–Associated Uveitis

open access: yesMedicine Advances, EarlyView.
HLA‐B27‐associated acute anterior uveitis causes significant inflammation of the iris and anterior chamber, which disrupts normal parasympathetic control and results in increased sympathetic tone leading to pupil dilation (mydriasis). This finding can sometimes resemble herpetic uveitis, making a clinical context and careful evaluation crucial for ...
Saim Mahmood Khan   +6 more
wiley   +1 more source

Filomicelle‐Embedded Composite Hydrogels for Localized Gelation Within the Anterior Chamber of the Eye

open access: yesSmall, EarlyView.
A composite hydrogel (C‐gel) incorporating PEG‐b‐PPS filomicelles enables localized in situ gelation and sustained nanocarrier release within the anterior chamber. The filamentous structure promotes spatial confinement of multi‐arm polymer crosslinking, even upon injection into large aqueous volumes, and gradually transitions into spherical micelles ...
Hyeohn Kim   +6 more
wiley   +1 more source

Phakic Intraocular Lenses An Overview

open access: yesDelhi Journal of Ophthalmology, 2013
Currently, there are four general approaches to correct refractive errors: refractive corneal surgery, crystalline lens surgery, and implantation of an intraocular lens (IOL) in the anterior or posterior chamber.
Sana Ilyas Tinwala, J S Titiyal
doaj   +1 more source

Clinical Outcomes and Cataract Formation Rates in Eyes 10 Years After Posterior Phakic Lens Implantation for Myopia. [PDF]

open access: yes, 2016
Intraocular collamer lenses (ICLs) are posterior chamber phakic lenses that provide a refractive surgery option for those with high myopia or astigmatism.
Bergin, C.   +5 more
core   +2 more sources

Home - About - Disclaimer - Privacy