Results 31 to 40 of about 4,045 (208)
Comparison of Total Thyroidectomy with Ligasure Small Jaw Device and Harmonic Scalpel
Objective: To compare our experience with the LigaSure small jaw device and Harmonic scalpel in total thyroidectomy regarding operative time and major complications associated with surgery. Study Design: Prospective comparative study.
Zaki Hussain Salamat +4 more
doaj +1 more source
Comparative Study of Bipolar Vessel Sealing Clamp versus Traditional Method for Vaginal Hysterectomy [PDF]
Background: Hysterectomy is a gynecological surgical procedure that has been linked to raised women morbidity and mortality. The two most common problems related to hysterectomy are bleeding and pain.
Esraa Ahmed +2 more
doaj +1 more source
Hartmann colostomy with ligasure
While LigaSure is commonly used for blood vessel closure, our aim was to research the effectiveness of using the latter tool for the purpose of closing intestines in rats.Twenty Wistar albino rats were divided into two groups per 10 each. In Group 1, the sigmoid colon was cut from its middle and its distal was closed with 4/0 silk.
O, Karahan +5 more
openaire +3 more sources
Background: Hemorrhoidectomy by LigaSure electrosurgical unit seems to be very effective treatment and results in better surgical outcomes when compared with the conventional excisional hemorrhoidectomy.
Ibrahim Falih Noori
doaj +1 more source
Safety and efficacy of LigaSure usage in pancreaticoduodenectomy [PDF]
Over recent years, use of the LigaSure™ vessel sealing device has increased in major abdominal surgery to include pancreaticoduodenectomy (PD). LigaSure™ use during PD has expanded to include all steps of the procedure, including the division of the uncinate margin.
Eng, Oliver S. +7 more
openaire +2 more sources
Laparoscopic Splenectomy: Comparative Study Between Using of Ligasure and Harmonic scalpel [PDF]
Background: Advanced laparoscopic solid organ surgery is now possible with the use of LigaSure and the Harmonic scalpel, which drastically cut down on operating time and blood loss.
Noura Younes +3 more
doaj +1 more source
Complications associated with energy‐based devices during thyroidectomy from 2010–2020
Objective Harmonic Focus (Ethicon, Johnson and Johnson, Cincinnati, OH, USA), LigaSure Small Jaw (Medtronic, Covidien Products, Minneapolis, MN, USA), and Thunderbeat Open Fine Jaw (Olympus, Japan) are electrosurgical instruments used widely in head and ...
Esther Lee +6 more
doaj +1 more source
Clinical Remission of an Unresectable Presumptive Haemangiosarcoma in a Dog Treated With Toceranib, Piroxicam, and Propranolol: A Case Report. [PDF]
Radiographic remission of a presumptive unresectable haemangiosarcoma treated with toceranib, piroxicam, and propranolol. In a dog with ACVIM Stage B2 myxomatous mitral valve disease where doxorubicin‐based chemotherapy was contraindicated, this multimodal regimen achieved marked tumour reduction and radiographic disappearance.
Park WD.
europepmc +2 more sources
LIGASURE VERSUS CLAMP AND TIE TECHNIQUE TO ACHIEVE HEMOSTASIS IN THYROIDECTOMY FOR BENIGN DISEASES
Background:Occurrence of adverse effects and advantages of the Ligasure diathermy system (or Ligasure vessel sealing system) in thyroidectomy have not been tested in prospective randomized studies comparing its use with that of the time-saving clamp-and ...
Tariq I Al-Aubaidi +2 more
doaj +4 more sources
This study compared burst pressure (BP), number of activations, and histological assessment of ex vivo swine small intestine loops transected by stapler, a single fulcrum radiofrequency vessel sealing (RFVS) device, and the newly-developed jaws RFVS ...
Luca Lacitignola +3 more
doaj +1 more source

