Analisa Pengaruh Letak Lightning Arrester untuk Memproteksi Trafo Daya Terhadap Tegangan Lebih [PDF]
Seiring dengan meningkatnya konsumen energi listrik di Indonesia, penyaluran energi listrik kepada konsumen di harapkan dapat berjalan dengan lancar.
Andika Putra +2 more
doaj +2 more sources
Analisis Persebaran Medan Listrik pada Lightning Arrester 20kV Menggunakan Finite Element Method [PDF]
Lightning Arrester adalah perangkat semikonduktor yang digunakan dalam sistem tenaga listrik untuk melindungi peralatan terhadap petir dan switching tegangan lebih.
Fahmi, D. (Daniar) +2 more
core +3 more sources
Mathematical simulation of operation of multi-chamber arrester for lightning protection of power lines: calculation of thermophysical properties of nonequilibrium plasma [PDF]
Protection of important energy facilities from direct lightning impact requires the creation of special devices for lightning protection in particular multi-chamber arresters.
Ivanov Dmitriy +6 more
doaj +2 more sources
Point cloud registration of arrester based on scale-invariant points feature histogram [PDF]
Arrester is an important lightning protection device in the electrical field. The parameters of arrester such as creepage distance, umbrella distance and diameter are important for product quality, but they are difficult to measure because the shape of ...
Wen Zhu +5 more
doaj +2 more sources
Analisis Kerja Rele Overall Differential pada Generator Unit I PLTA Ketenger PT Indonesia Power UBP Mrica [PDF]
Plant has two important equipment that are the generator and transformer. Therefore, it should be protected well by the overall differential relay. This relay must be reliable from the disturbances that might arise.
Hari Prasetijo, Firman Arif Romadhona
doaj +5 more sources
Lightning Arrester Spark Gaps [PDF]
Chester T. Allcutt
openaire +3 more sources
STUDY ON SURGE ARRESTER PERFORMANCE DUE TO LIGHTNING STROKE IN 20 KV DISTRIBUTION LINES
Electric energy has been transmiting from power station to end user with transmission and distribution lines.Lightning strokes are problems that occure in transmission and distribution lines and make them fault when theelectric energy were transmited ...
Agung Warsito +2 more
doaj +1 more source
Onshore wind farms are usually connected to the power grid by 35 kV transmission lines. Due to the high altitude of the wind turbines and their associated long transmission corridors, lightning activities are more frequent for onshore wind farms compared
Chen Chen, Jiuguo Gao, Penghao Chu
doaj +1 more source
Pada jaringan distribusi tenaga listrik sering mengalami gangguan yang dapat menyebabkan kerugian , salah satu penyebab gangguan yang terjadi pada jaringan distribusi tenaga listrik adalah sambaran petir yang mengakibatkan tegangan lebih dan dapat ...
Dicky Satya Prawira +3 more
doaj +1 more source
Failure Risk Assessment of Surge Arrester Using Paralleled Spark Gap
Surge arresters are usually used to protect distribution feeders against randomly distributed lightning overvoltages. However, there is a probability of surge arrester failure due to an increase in its absorbed energy over the withstand capability.
Nehmdoh A. Sabiha +2 more
doaj +1 more source