Lightning Performance on Overhead Distribution Lines : After Improvement Field Observation [PDF]
Two feeders of 20 kV overhead distribution lines which are located in a high lightning density area are chosen to be observed as a field study due to their good lightning performance after improvement of lightning protection system.
Reynaldo Zoro +3 more
doaj
Development and application of lightning flashover limited equipment for 220 kV AC transmission line
In order to solve the operation problems of traditional lightning protection equipment (for example, line arrester and parallel gap) for 220 kV AC transmission line, a novel lightning protection equipment – lightning flashover limited equipment for 220 ...
Wei Cao +6 more
doaj +1 more source
Pemasangan Arrester Multi Chamber Untuk Mengatasi Gangguan Surja Petir di Penyulang Pecatu
Pecatu feeder is a feeder that has a radial distribution system configuration, the length of the line is 31 kms . In addition, these feeders have as many as 105 pieces of distribution transformers with a total number of subscribers reached 11,800 ...
I Gede Gerry Julius Perdana +2 more
doaj +1 more source
Modeling Metal Oxide Surge Arrester for the Modern Polarization Based Diagnostics [PDF]
Recently a number of new non-destructive diagnostic techniques have been investigated for the reliable condition assessment of the ageing of metal oxide surge arrester (MOSA).
Mardira, K. P., Saha, T. K.
core +1 more source
Study on variations in moisture-affected fault characteristics of EMU lightning arrester
In order to study the changes in the fault characteristics of the EMU lightning arresters exposed to moisture, an artificial moisture test platform of lightning arresters was built, on which the lightning arrester can be controlled to reach three states ...
LIU Jian +5 more
doaj
Lightning stroke causes a current injection into transmission lines at the point of contact. The lightning performance can be difficult to understand without using simulation programs.
Mohammed Qais, Usama Khaled
doaj +1 more source
Mitigation of Lightning Overvoltages Using STATCOM in Grid-Connected PV Systems [PDF]
Lightning strike causes a large lightning voltage injection into grid-connected PV systems at the point between inverter and transformer. The overvoltage resulting from the lightning-impulse voltage is a major concern for the multiple expensive ...
ibrahim hamdeen +2 more
doaj +1 more source
In view of problem that rotary motor of direct distribution line is easy to be damaged by lightning, the paper analyzed status of lightning protection of direct distribution line of ventilator station of a coal mine and its problems, indicated that the ...
ZHOU Yilong +5 more
doaj +1 more source
The Testing Of High Voltage Silicon Carbide Lightning Arresters
The majority of high voltage gapped silicon carbide lightning arresters on transmission and sub transmission systems have been in service for over 10 years.
Arkan A. Hussein
doaj +1 more source
Analysis of transmission lightning arrester locations using Tflash [PDF]
Tropical countries with extensive lightning activity, such as Malaysia, encounter numerous problems on their electrical transmission and distribution systems.
Arief, Y. Z. +8 more
core +1 more source