Lightning Arresters [PDF]

open access: yesScientific American, 1896
n ...
openaire   +1 more source

Application and Analysis for Surge Arrester on Lightning Protection of Distribution Network

open access: yesMATEC Web of Conferences, 2015
In order to effectively reduce lightning stroke outage rate, effect of lightning protection with surge arrester on transmission line has been generally acknowledged relative to other lightning protection measures.
Wang Daxing   +5 more
doaj   +1 more source

Evaluation of a Direct Lightning Strike to the 24 kV Distribution Lines in Thailand

open access: yesEnergies, 2019
This paper evaluates the effect of a lightning strike directly on the 24 kV distribution lines in Thailand, where such strikes are one of the main causes of power outages.
Pornchai Sestasombut   +1 more
doaj   +1 more source

Tower grounding improvement versus line surge arresters: comparison of remedial measures for high-BFOR subtransmission lines [PDF]

open access: yes, 2015
This paper presents a technical/economic comparison between remedial measures aimed at improving the lightning performance of an existing Italian three-phase 150-kV overhead line.
GATTA, Fabio Massimo   +4 more
core   +1 more source

Concept and Application of Lightning Arrester for 11kV Electric Power Systems Protection

open access: yes, 2020
Copyright@2020 AJBSR www.ajbsr.net Page | 35 Nomenclature R1 = Filter resistance XL1 = Filter inductive reactance μH = Micro-Henry, sub unit of Inductance Ω = Ohm, unit of Resistance L1 = Filter inductance C = Terminal-to-terminal Capacitance of Arrester
Uche Chinweoke Ogbuefi   +2 more
semanticscholar   +1 more source

Estimation of parameters of metal-oxide surge arrester models using Big Bang-Big Crunch and Hybrid Big Bang-Big Crunch algorithms [PDF]

open access: yesJournal of Artificial Intelligence and Data Mining, 2016
Metal oxide surge arrester accurate modeling and its parameter identification are very important for insulation coordination studies, arrester allocation and system reliability.
M.M Abravesh   +3 more
doaj   +1 more source

Lightning Performance on Overhead Distribution Lines : After Improvement Field Observation [PDF]

open access: yesITB Journal of Engineering Science, 2009
Two feeders of 20 kV overhead distribution lines which are located in a high lightning density area are chosen to be observed as a field study due to their good lightning performance after improvement of lightning protection system.
Reynaldo Zoro   +3 more
doaj  

Development and application of lightning flashover limited equipment for 220 kV AC transmission line

open access: yesThe Journal of Engineering, 2019
In order to solve the operation problems of traditional lightning protection equipment (for example, line arrester and parallel gap) for 220 kV AC transmission line, a novel lightning protection equipment – lightning flashover limited equipment for 220 ...
Wei Cao   +6 more
doaj   +1 more source

Mitigation of Lightning Overvoltages Using STATCOM in Grid-Connected PV Systems [PDF]

open access: yesPort Said Engineering Research Journal, 2020
Lightning strike causes a large lightning voltage injection into grid-connected PV systems at the point between inverter and transformer. The overvoltage resulting from the lightning-impulse voltage is a major concern for the multiple expensive ...
ibrahim hamdeen   +2 more
doaj   +1 more source

Pemasangan Arrester Multi Chamber Untuk Mengatasi Gangguan Surja Petir di Penyulang Pecatu

open access: yesMajalah Ilmiah Teknologi Elektro, 2018
Pecatu feeder is a feeder that has a radial distribution system configuration, the length of the line is 31 kms . In addition, these feeders have as many as 105 pieces of distribution transformers with a total number of subscribers reached 11,800 ...
I Gede Gerry Julius Perdana   +2 more
doaj   +1 more source