Results 121 to 130 of about 2,833,637 (301)

Evaluation Methodology, Numerical Verification and Retrofilling Procedure for Power Transformers to Ensure K‐Class Flame Retardancy and Environmentally Friendly

open access: yesHigh Voltage, EarlyView.
ABSTRACT With increasing demands for fire safety and environmental friendliness, retrofilling transformers with alternative insulating liquids has become a growing trend. However, retrofilling power transformers remains uncertain, as more residual mineral oil compromises K‐class flame retardancy, and its impact on environmental performance has yet to ...
Zhenfu Tang   +5 more
wiley   +1 more source

Comparison of Dielectric Recovery After Arc Burning in SF6 Gas and Its Potential Alternatives

open access: yesHigh Voltage, EarlyView.
ABSTRACT Although sulphur hexafluoride (SF6) exhibits exceptional insulating properties, it is a potent greenhouse gas. Therefore, studying alternatives to SF6 is critical for developing environmentally friendly high‐voltage electrical equipment.
Ziqi Liu   +4 more
wiley   +1 more source

GMM-Based Lightning Damage Detection for Wind Turbines Under De-Rated Operation Using the Scaled Power Curve

open access: yesEnergies
Many countries are actively promoting the large-scale deployment of wind power generation, both onshore and offshore. However, damage to wind turbines caused by winter lightning has become a growing concern in Japan. Japan has made efforts since an early
Takuto Matsui   +2 more
doaj   +1 more source

U.S. LIGHTNING STRIKE DEATHS [PDF]

open access: yes
The risk of being struck by lightning is low, but the consequences of being struck by lightning ARE SERIOUS.To learn more about lightning, visit: www.cdc.gov/disasters/lightning\u2022 444- From 2006 through 2021, 444 people in the 444 United States died ...

core  

Computation of electromagnetic fields from lightning discharge

open access: yes, 2014
Electromagnetic fields from lightning can couple to electrical systems and produce transient overvoltages, which can cause power and telecommunication outages and destruction of electronics.
Rajeev Thottappillil   +1 more
core   +1 more source

Rare Lightning and Convection Characteristics During Two Successive Tornadoes in Southern China

open access: yesHigh Voltage, EarlyView.
ABSTRACT Systematic investigations into lightning characteristics of tornado storms in China remain scarce. This study comprehensively analyses rare lightning behaviour and overshooting top characteristics for two successive tornadoes during a long‐lived supercell in southern China on 27 April 2024.
Fengquan Li   +9 more
wiley   +1 more source

Clinical and self‐reported measurements to be included in the core elements of the World Dental Federation's theoretical framework of oral health

open access: yesInternational Dental Journal, EarlyView., 2020
Introduction Oral health is part of general health, and oral diseases share risk factors with several non‐communicable diseases. The World Dental Federation (FDI) has published a theoretical framework illustrating the complex interactions between the core elements of oral health (CEOHs): driving determinants, moderating factors, and general health and ...
Hanna Ahonen   +5 more
wiley   +1 more source

Lightning Impulse Ageing of HV Cable Insulation

open access: yes, 2009
Lightning impulses can lead to accelerated ageing of extruded cables. Electrical behaviour of a dielectric material when experiencing a lightning impulse is different to that for DC or power frequency applied voltages.
Dao, N L, Swingler, S G, Lewin, P L
core   +1 more source

Assessment of Lightning Activity and Early Warning Capability Using Near-Real-Time Monitoring Data in Hanoi, Vietnam

open access: yesAtmosphere
This study investigates lightning activity and evaluates a near-real-time lightning warning system for the inner Hanoi area, using data collected during 2020–2024 from the Strike Guard (SG) and EFM-100C instruments located in Chuong My, Hanoi, Vietnam ...
Hoang Hai Son   +12 more
doaj   +1 more source

Investigation of the Evolution Mechanism and Multiphysics Coupling in Tree‐Contact Single‐Phase‐to‐Ground Fault

open access: yesHigh Voltage, EarlyView.
ABSTRACT Tree‐contact single‐phase‐to‐ground fault (TSF) is a common and hazardous type of failure in distribution networks. TSF is likely to occur when overhead conductors contact moist tree branches, potentially leading to insulation breakdown, posing serious threats to grid safety.
Wenjun Ning   +5 more
wiley   +1 more source