Results 21 to 30 of about 314,581 (221)
The impulse grounding impedance of tower grounding device is one of the important factors in the lightning protection evaluation of transmission line. The impulse characteristic test of the actual tower grounding device under lightning was rarely carried
Yi Zhang +7 more
doaj +1 more source
Modeling of different tower grounding systems using hybrid continuous circuit-trapezoidal integration method [PDF]
In order to protect the transmission lines against lightning strikes, it is important to investigate the tower grounding system. In this paper, a recent method called hybrid continuous circuit-trapezoidal integration method is used to calculate ...
Asadpourahmadchali Mohammadbagher +2 more
doaj +1 more source
Equivalent circuit model of tower based on full-wave analysis
The tower model is very important for the assessment of lightning protection for transmission line. The parameters of tower model mainly rely on the impulse experiments of tower.
Chun Li +6 more
doaj +1 more source
Evaluation of Lightning Impulse Test by Frequency Response Analysis [PDF]
In this work are presented the basis for improving the interpretation of transformer lightning impulse test and the development of a graphical user interface system, which allows comparisons of time domain data and frequency response.
Jorge Ramirez +3 more
core +3 more sources
The Qinghai-Henan ±800kV UHV DC power transmission project is an UHV channel specially constructed for clean energy delivery, ±800kV converter transformers of the project are assembled and tested in Xining at an altitude of 2500 m, full-wave lightning ...
Ling Jiang +12 more
doaj +1 more source
Tower impulse grounding resistance measurement based on multiple frequency impedance
Tower impulse grounding resistance is important for judging the lightning protection performance of transmission lines. Therefore, it is significant to accurately measure the tower impulse grounding resistance. Existing measurement methods mainly contain
Yihua Dan +5 more
doaj +1 more source
To meet the special insulation demand of the DC transmission system with the highest voltage in the world, a new kind of ±1 100 kV DC voltage divider is designed.
Wu Shipu +4 more
doaj +1 more source
Impacts of Lightning-Induced Overvoltage on a Hybrid Solar PV–Battery Energy Storage System
With increased electrical energy demands projected in the future, the development of a hybrid solar photovoltaic (PV)–battery energy storage system is considered a good option. However, since such systems are normally installed outdoors and in open areas,
Nor Izzati Ahmad +5 more
doaj +1 more source
Based on the operation situation of the lightning arresters commonly used in Shaanxi Province, a lightning arrester with multi-short-gaps is developed, which has excellent ability in extinguishing arc.
Zeli JU +6 more
doaj +1 more source
Due to the intermittent and hazardous nature of lightning impulse, researchers rely on artificial impulse generators to study it. The Tesla coil is a commonly used device to generate artificial lightning.
Suman Jana +3 more
doaj +1 more source

