Results 31 to 40 of about 314,581 (221)
This simulation study presents the effect of lightning strikes on the performance of arresters at 150 kV overhead lines. Lightning strikes have several parameters that affect the performance of line arresters (LA), namely lightning charge, and impulse ...
Fri Murdiya +4 more
doaj +1 more source
The observation of the air gap discharge process is the basis of revealing the physical mechanism of gas discharge and establishing the accurate numerical simulation model.
Yaqi Zhang +7 more
doaj +1 more source
10/350 µs Lightning Impulse Current Behavior of a Conductive Fabric
Lightweight Portable Lightning Protection Shelters require the use of new materials capable of supporting the high current densities associated with lightning currents.
Acosta, Cristian, +13 more
core +1 more source
As one of the key technologies to solve the problem of high short-circuit current, the fault current limiter (FCL) has become a research hotspot in China and abroad.
Changfu Chen +8 more
doaj +1 more source
Gaseous by-products of a CF3I-CO2 gas mixture under lightning impulse and AC breakdowns
This paper examines the use of a CF3I-CO2 gas mixture as an environmentally friendly insulation medium in high voltage gas insulated equipment. The gaseous by-products of a 30:70% CF3I:CO2 (Trifluoroiodomethane – Carbon dioxide) gas mixture are examined ...
Haddad, A, Widger, Phillip
core +5 more sources
Long-Range Lightning Interferometry Using Coherency
Traditional lightning detection and location networks use the time of arrival (TOA) technique to locate lightning events with a single time stamp. This contribution introduces a simulation study to lay the foundation for new lightning location concepts ...
Xue Bai, Martin Füllekrug
doaj +1 more source
Lightning Impulse Current Tests on some Electroconductive Fabrics [PDF]
On the search of lightweight lightning protection materials that can be used as part of lightning protection systems, we investigate some types of electroconductive fabrics by applying several lightning impulse currents in laboratory.
Q., Liz K. Herrera +11 more
core +1 more source
Observations of X-ray in 4-meters long laboratory sparks under positive lightning impulse
In this paper, the observation of X-rays in 4-meters long laboratory sparks is presented for the first time. In this study, a total of 20 standard positive lightning impulse voltages (1.2/50 mu s) with measured peak voltages between 3.0 to 3.2 MV were ...
Andre Lobato +9 more
core +1 more source
Investigation of lightning ignition characteristics based on an impulse current generator
Lightning strike is an important ignition source of forest fires. Artificial lightning discharge is a method for studying lightning fires. However, there is not enough data on the ignition of combustible materials caused by artificial lightning discharge.
Junwei Feng, Hao Shen, Dong Liang
doaj +1 more source
Lightning strike is the main reason for the transmission line tripping. Studies on the insulator flashover characteristics and the accurate flashover criteria under the lightning impulse are the basis for correctly evaluating the lightning resistance ...
Yongxia Han +7 more
doaj +1 more source