Evaluation of a Direct Lightning Strike to the 24 kV Distribution Lines in Thailand
This paper evaluates the effect of a lightning strike directly on the 24 kV distribution lines in Thailand, where such strikes are one of the main causes of power outages.
Pornchai Sestasombut +1 more
doaj +1 more source
Lightning Evaluation of Overhead Transmission Line Protected by EGLA
Lightning is the main factor of outage and insulation breakdown of power system. The lightning event can produce dangerous overvoltage, equipment failures, and power supply interruption.
M. Khodsuz
doaj
Distributed photovoltaic systems: Utility interface issues and their present status [PDF]
Major technical issues involving the integration of distributed photovoltaics (PV) into electric utility systems are defined and their impacts are described quantitatively.
Hassan, M., Klein, J.
core +1 more source
Numerical Modeling And Simulation In Electromagnetic Transient Program For Estimating Line Backflashover Performance [PDF]
This paper presents a numerical modeling and simulation of 132 kV transmission line in electromagnetic transient program and later predicts the critical backflashover current, probability of the transformer damage and backflashover rate (BFR) when ...
Ab Kadir, Mohd Zainal Abidin +2 more
core
Analysis of Surge Propagation with Lightning Arrester using FDTD for 25 kV-AC Transmission Line [PDF]
This paper analyzes lightning surge propagation and reflection as the surge arrives at a lightning arrester. Telegraphist equations have been used to characterize the voltage and current of a travelling wave in a lossless power transmission line and ...
Aodsup, K. (Kokiat) +1 more
core
Rural Facility Electric Power Quality Enhancement [PDF]
Electric power disturbances are known to be more prevalent in small, isolated power systems than in larger interconnected grids which service most of the United States. This fact has given rise to a growing concern about the relative merits of different
Aspnes, J.D. +3 more
core
Анализ грозозащиты высоковольтной подстанции на напряжение 330 кВ [PDF]
Работа содержит 88 листов, 14 рисунков, 19 таблиц, 19 используемых источника. Ключевые слова: грозозащита, кривая опасных параметров, волна перенапряжения, вентильный разрядник, стержневые молниеотводы, заземлитель, длина защитного подхода, показатель ...
Прохоренко, Алексей Владимирович
core
A Smart Grid Overvoltage Identification System Associated with Partial Discharge Signal and Dielectric Loss Detection. [PDF]
Chen G +6 more
europepmc +1 more source
Simulation and Analysis of Lightning Backflashover for the 132 Kv Kuala Krai–Gua Musang Transmission Line Using PSCAD [PDF]
Lightning has been a major concern to the power system researchers as it may cause damage to the connected electrical equipment especially to the transmission line.
Sardi, Junainah
core